Cci readerinstall header

Install Mounting Hardware

Cci readerinstall kit
KitID980
  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to for further instructions.

Connect Power

Power is supplied through the same Machine Interface Harnessdescribed in step 4.

Connect Coin Sense Harness

Not applicable in this setup. FasCard reader does not collect payment from any other devices, and will only send funds to the machine's control.

Connect Machine Interface Harness

Cci readerinstall kit
KitID839
KitDescSerial
  1. Connect theC-6124-MDB Machine Start Harness to theMDB connection on the Machine Control Assembly.
    1. Optional: Use the pigtail MDB connector to reconnect any existing payment devices.

Connect and Mount Reader

Multiexcerpt include
SpaceWithExcerptCCIDOC
MultiExcerptNameF2 Reader
PageWithExcerpt_Reader Ports

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.
  1. Feed remaining harness ends through the mounting hole as described in theFasCard Mounting Guide.
  2. Connect the black, 10-pin connection of theC-6124-MDBMachine Start Harnessto port 5 (Serial Connection Port) as shown in the image above.
  3. Connect the clear, 3-pin connection of theC-6124-MDBPower Harness to port 1.
  4. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration