Cci readerinstall header

Install Mounting Hardware

Cci readerinstall kit
KitID584
KitDescCoin and Card
  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to for further instructions.

Cci readerinstall kit
KitID1013
KitDescCard Only - Metercase Model
  1. Remove existing coin drop and coin box from the metercase.
  2. Attach theC-5414 F2 Mounting Bracketto the C-6912 Metercase Bracketusing(2)C-542010-32 x 1/4 Pan Screws.
  3. Run the C-5500 Power Extension Harness and C-5355 Machine Start Harness through the metercase and then through the circular opening in the C-6912 Metercase Bracket.
  4. Insert the assembled C-6912 Metercase Bracket into the metercase and secure from the inside using the C-1059 Keps Nuts.

Connect Power

Cci readerinstall kit
KitID595
KitDescSpade Tap Power Converter
  1. Use the C-5101 Spade Taps on the incoming power.
    1. Tap the black L1 wire.
    2. Tap the white N wire.
    3. Tap the green G wire.
  2. Take the C-5210 Power Adapter Harness and connect the red tab connectors to the following wires:
    1. Connect the blue wire to the black L1 wire.
    2. Connect the brown wire to the white N wire.
    3. Connect the green/yellow wire to the green G wire.
  3. Connect the 3-pin connector from the C-5210 Power Adapter Harness to the matching connection on the C-5602R1 Power Converter.
  4. Connect the 4-pin connector from the C-5602R1 Power Converter to the matching connection on the C-5500 Power Extension Harness.

Connect Coin Sense Harness

Cci readerinstall kit
KitID715
KitDescOptical Coin Sensor
  1. Connect the C-6352-40 Machine Start Harness to the Coin 1 Connection located inside the metercase.

Connect Machine Interface Harness

Cci readerinstall kit
KitID658
KitDescSerial Communication Harness
  1. Connect the C-5355 Machine Start Harness to the CN4 Payment Device Connection located inside the metercase.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole.
  2. Connect the free end of the C-5355 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
  3. (Coin and Card Installations Only) Connect the free end of the C-6352-40 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.

Machine Configuration

Multiexcerpt include
SpaceWithExcerptCCIDOC
MultiExcerptNameEncore - FLW
PageWithExcerpt_Machine Configuration

Cci readerinstall footer