- Disconnect the Coin Drop from the Machine Control Assembly.
- This harness must remain disconnected for FasCard to function properly. Reconnecting this harness after installation will damage FasCard reader. Technical Support recommends taping off these connections.
- Bridge the solid Red and solid Blue wires coming from thecoin eyesensor using theC-5260Wire Tap Bridge.
- Bridge the Blue/Silver and solid Purple wires going to the machine control assemblyusing theC-5260Wire Tap Bridge.
- Tap the Red, White, and White/Blue wires with theC-5101Spade Taps provided.
- Connect theC-5361Coin Sense Harnessto the installed spade taps.
- Red connects to Red.
- Blue connects to White/Blue.
- White connects to White.
|