Disconnect the Coin Drop from the Machine Control Assembly. This harness must remain disconnected for FasCard to function properly. Reconnecting this harness after installation will damage FasCard reader. Technical Support recommends taping off these connections.
Bridge the solid Red and solid Blue wires coming from the coin eye sensor using the C-5260 Wire Tap Bridge. Bridge the Blue/Silver and solid Purple wires going to the machine control assembly using the C-5260 Wire Tap Bridge. Tap the Red, White, and White/Blue wires with the C-5101 Spade Taps provided. Connect the C-5361 Coin Sense Harness to the installed spade taps. Red connects to Red. Blue connects to White/Blue. White connects to White.
|