Cci readerinstall kit |
---|
Cci readerinstall kit |
---|
KitID | 905 |
---|
KitDesc | Card Only - Card Ready Models |
---|
| Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
Cci readerinstall kit |
---|
KitID | 861 |
---|
KitDesc | Card Only - Rear Control Coin Drop Model |
---|
|
Remove the coin drop and coin box.
Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.
Secure C-5414 F2 Mounting Bracket to the C-6903 Mounting Bracket using the (2)C-5420 10-32 x 1/4 Pan Screws.Attach the C-5760-A Adapter Bracket to the C-6762 Mounting Bracket to the captured nut on the inside of the C-6762 Mounting Bracket.
Run all reader harnesses through the metercase and out the opening where the coin drop normally mounts.
Run all reader harnesses through the circular opening on the C-6762 Mounting Bracket.
Install the C-6762 Mounting Bracket into the front opening of the metercase so the two threaded posts of the C-5760-A Adapter Bracket line up with the openings for the coin slots. Secure in place using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.
KitID | 857 |
---|
KitDesc | Card Only - 10° Panel Coin Model |
---|
|
Remove existing coin box and coin drop. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness. Attach the C-5414 F2 Mounting Bracket to the C-6765-W-R1 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws. Run any card reader harnesses through the coin slot openings and the circular hole in the C-6765-W-R1Metercase Bracket. Install the C-6765-W-R1 Metercase Bracket so that the two threaded posts insert into the coin drop slots. Then secure it to the machine using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.
|
...
...
...
...