Remove the coin drop and coin box.
Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.
Secure C-5414 F2 Mounting Bracket to the C-6903 Mounting Bracket using the (2)C-5420 10-32 x 1/4 Pan Screws.
Attach the C-5760-A Adapter Bracket to the C-6762 Mounting Bracket to the captured nut on the inside of the C-6762 Mounting Bracket.
Run all reader harnesses through the metercase and out the opening where the coin drop normally mounts.
Run all reader harnesses through the circular opening on the C-6762 Mounting Bracket.
Install the C-6762 Mounting Bracket into the front opening of the metercase so the two threaded posts of the C-5760-A Adapter Bracket line up with the openings for the coin slots. Secure in place using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.