Install Mounting Hardware

  • Mount C-6762 Metercase Bracket into the front of the metercase, inserting the two studs through the coin slot openings.

    1. Secure to the metercase using (2) C-1059 Kep Nuts and (2) C-1070-W Washers.

  • Place the C-6700-TEMP Drill Template on the desired mounting location.

  • Verify included harnesses will reach desired location without encountering interference from internal machine components.

  • Refer to FasCard Mounting Guide for further instructions.
  • Remove existing coin box and coin drop.

  • Bridge the Coin Vault Switch connections using C-5365 Bypass Harness.

  • Attach C-5760-A Alliance Adapter Bracket to C-6762 Metercase Bracket.

  • Attach the C-5414 Mounting Bracket to C-6762 Metercase Bracket using the (2)C-5420 10-32 x 1/4 Pan Screws.
    Cci readerinstall kit
    Cci readerinstall kit
    KitID584
    KitDescCoin and Card
    Cci readerinstall kit
    KitID861
    KitDescCard Only - Coin Model w/ High Capacity Metercase
    KitID916
    KitDescCard Only - Coin Model w/ Standard Metercase
    1. Remove existing coin box and coin drop.

    2. Attach C-5760-A Alliance Adapter Bracket to C-6760 Metercase Bracket.

    3. Attach the C-5414 Mounting Bracket to C-6760 Metercase Bracket using the (2)C-5420 10-32 x 1/4 Pan Screws.

    4. Mount C-6760 Metercase Bracket into the front of the metercase, inserting the two studs through the coin slot openings.

      1. Secure to the metercase using (2) C-1059 Kep Nuts and (2) C-1070-W Washers.

    ...

    Cci readerinstall kit
    KitID636
    KitDescPulse - Hybrid Coin Slide Control
    1. Connect the C-5256 Machine Start Harness to the manufacturer's harness previously connected to the micro switch used by the coin slide.

    Connect and Mount Reader

    ...

    Reader

    ...

    Feed remaining harness ends through the mounting hole.

    ...

    (Hybrid Coin Slide Controls Only) Connect the free end of the C-5256 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    ...

    (ACA/Titanium Controls Only) Connect the free end of the C-5240 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

    ...

    (Coin and Card Install Only) Connect the free end of the C-6250 or C-6253 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    ...

    Machine Configuration

    Multiexcerpt include
    SpaceWithExcerptCCIDOC
    MultiExcerptNameACA Configuration
    PageWithExcerpt_Machine Configuration

    ...