This programming method requires both a CCI Program card and a C-0103 model card reader as shown above.
Programming Steps
1. Identify desired unit address for card reader.
2. Reboot power to card reader. 3. Insert Program card, reader will display:
Set Address: 0** Dip Card to Set
4. To increase current digit: Insert tip of card and remove quickly. 5. To move to next digit: Insert card fully and wait (approx 2 seconds). 6. After accepting last digit of unit address, reader will display:
Storing Value Remove Card Now
Card Reader Programming instructions.pdf
Ui tab
title
C-0101 Card Reader Dip Switch Programming
Programming Card Reader Model C-0100
Programming Requirements
This programming method requires a C-0100 model card reader as shown above.
Programming Steps
1. Identify desired unit address for card reader.
2. Depress dip switches in combination to equal the unit address value. See below for an explanation of dip switching.
Dip Switch Selection Process
Each switch has a value associated with it, as shown in the table below. Turning switches on causes their values to be added together.
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
128
64
32
16
8
4
2
1
For example turning switch numbers 8 (1) and 7 (2) on represents the value of 3, or turning on switch numbers 4 (16), 6 (4), and 8 (1) equals 21. Using this binary chart you can achieve any number between 1 and 255.
Once a card reader has been addressed, the reader will display that address across its LCD screen when it is plugged into the system. Once the system recognizes that the reader is online, the reader displays 'Vend Price xxxx'. When the reader is running you can place the reader into a diagnostics mode with the Diag Card, and it will display its programmed address.
The following PDF may be used to help you properly set the switches to represent the desired card reader address. Find the desired reader address in the table and set the switches to the correct associated On/Off settings.