Insert Program card, reader will display: Set Address: 0** Dip Card to Set
To increase current digit: Insert tip of card and remove quickly.
To move to next digit: Insert card fully and wait (approx 2 seconds).
After accepting last digit of unit address, reader will display: Storing Value Remove Card Now
Card Reader Programming instructions.pdf
Ui tab
title
C-0100 Card Reader Dip Switch Programming
Items Needed
Card Reader (C-0100)
Programming Steps
Identify desired unit address for card reader.
Set dip switches in combination to equal the unit address value. See below for an explanation of dip switching.
Dip Switch Values
Each switch has a value associated with it, as shown in the table below. Turning switches ON causes their values to be added together.
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
128
64
32
16
8
4
2
1
For example turning switch numbers 8 (1) and 7 (2) on represents the value of 3, or turning on switch numbers 4 (16), 6 (4), and 8 (1) equals 21. Using this binary chart you can achieve any number between 1 and 255.