This page is intended to guide the user through the replacement of a failed network switch within the X-Changer cabinet.

Multiexcerpt include
MultiExcerptNameWarning
DisableCachingtrue
PageWithExcerptCCIDOC:_General

Required Hardware

Bw part list
Partsc-0629
ShowDesc2false
ShowDesc3false

Recommended Tools and Supplies (Not Included)

No.2 Phillips Screwdriver
(Or Equivalent)
 

Image Modified

Installation

DivClassinstall-steps

Panel

Step 1 - Identify the Network Switch

Image Modified

  1. Open the front door of the X-Changer cabinet.
  2. Locate the network switch.
    1. The network switch in the image above is framed in green.
    2. The network switch looks similar to the control head, framed in red. It is critical for store operation that lines are not removed from the control head.
      1. If the network switch cannot be identified, contact Technical Support for assistance.
panel

Step 2 - Disconnect Switch from Power

Image Modified

  1. Open the rear door of the X-Changer cabinet.
  2. Locate the rear of the network switch, framed in green.
  3. Trace the power cable from the switch to the outlet.
  4. Disconnect power cable from outlet.
    1. Note the outlet for the new switch.
Panel

Step 3 - Remove the Existing Network Switch

Image Modified

  1. Disconnect all cables connected to the front of the network switch.
    1. Take note of how many/which cables are connected to the network switch - Technical Support recommends taking a smartphone picture.
  2. Remove the screws (framed in red) mounting the network switch to the X-Changer framework.
    1. Set screws aside for mounting replacement switch.
  3. Slide the network switch forward and remove through the front door of the X-Changer cabinet.
panel

Step 4 - Install the Replacement Network Switch

Bw part list
PartsC-0629
SizingModeHeight
ShowDesc2false
ShowDesc3false
SingleRowtrue

  1. Feed the power cable for the new network switch through the opening in the X-Changer framework.
  2. The bracket (not shown) will line up with the mounting holes for the previous switch.
  3. Mount network switch with screws removed in step 3.
  4. Reconnect cables to front of network switch removed in step 3.
    1. The exact port does not matter - all ports will function in the same fashion.
  5. Reconnect power cable in rear of X-Changer in reverse of step 2.
  6. Contact Technical Support to test.