Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Access and connect to the store number you are extending in LaundryLink.

  2. Open the CCI.INI file for every X-Changer for editing.

    1. This can be done through opening the file via LaundryLink itself or through the X-Changer remotely using the Remote Control function in LaundryLink.

    2. When done remotely, you can use Laundry App Utility to access the file. The file itself can be found in <D:\CCI\Process_Initialization>

  3. With CCI.INI opened, navigate to [STATE_MACHINE] and add the following line:
    MAX_MACHINE_ID= _ _ _
    The three numbers entered can be any number between 255-320 but no higher (e.g. MAX_MACHINE_ID=320).

    Image RemovedImage Added

  4. Save the change and repeat this process for every X-Changer’s CCI.INI file.

  5. Restart all X-Changer applications across all X-Changers.

...

  • Users cannot enter a Card Reader Address above 255. The card readers themselves cannot be programmed past 255 254 successfully.

  • Users CAN override the Card Reader Address. When selecting a Machine ID above 254, you can override the Card Reader Address to any desired number between 1 and 254. With that said:

  • Users CAN assign the same Card Reader Address on Different Line Numbers. For example, you can have any Card Reader Address between #001 and #255 #254 on Line Numbers 0, 1, 2, 3, 4, and/or 5, as long as the correct Machine ID is selected.

...