Overview
This page is intended to guide the user through the replacement of a failed network switch within the X-Changer cabinet.
Multiexcerpt include | ||||||
---|---|---|---|---|---|---|
|
Required Hardware
Bw part list | ||||||
---|---|---|---|---|---|---|
|
Recommended Tools and Supplies (Not Included)
No.2 Phillips Screwdriver (Or Equivalent) |
Installation
Step 1 - Identify the Network Switch
- Open the front door of the X-Changer cabinet.
- Locate the network switch.
- The network switch in the image above is framed in green.
- The network switch looks similar to the control head, framed in red. It is critical for store operation that lines are not removed from the control head.
- If the network switch cannot be identified, contact Technical Support for assistance.
Step 2 - Disconnect Switch from Power
- Open the rear door of the X-Changer cabinet.
- Locate the rear of the network switch, framed in green.
- Trace the power cable from the switch to the outlet.
- Disconnect power cable from outlet.
- Note the outlet for the new switch.
Step 3 - Remove the Existing Network Switch
- Disconnect all cables connected to the front of the network switch.
- Take note of how many/which cables are connected to the network switch - Technical Support recommends taking a smartphone picture.
- Remove the screws (framed in red) mounting the network switch to the X-Changer framework.
- Set screws aside for mounting replacement switch.
- Slide the network switch forward and remove through the front door of the X-Changer cabinet.
Step 4 - Install the Replacement Network Switch
Bw part list | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
- Feed the power cable for the new network switch through the opening in the X-Changer framework.
- The bracket (not shown) will line up with the mounting holes for the previous switch.
- Mount network switch with screws removed in step 3.
- Reconnect cables to front of network switch removed in step 3.
- The exact port does not matter - all ports will function in the same fashion.
- Reconnect power cable in rear of X-Changer in reverse of step 2.
- Contact Technical Support to test.