Overview
Card reader programming varies depending upon card reader model. Select the appropriate tab below, based upon card reader model number.
...
Programming Instructions
Expand |
---|
title | Dip Switch Programming |
---|
|
Items Needed |
Super Card (C-2SUPERCARD) | Card Reader (C-0101, C-0102, C-0103) | OPTIONAL: Reader 9v Battery (C-0095) |
---|
Programming Steps
- Identify desired unit address for card reader.
- Power cycle card reader.
- Insert Program card, reader will display:
Set Address: 0**
Dip Card to Set
- To increase current digit: Insert tip of card and remove quickly.
- To move to next digit: Insert card fully and wait (approx 2 seconds).
- After accepting last digit of unit address, reader will display:
Storing Value
Remove Card Now
Card Reader Programming instructions.pdf Ui tab |
---|
title | C-0100 Card Reader Dip Switch Programming |
---|
|
Items Needed
Card Reader (C-0100) |
---|
Bw part list |
---|
Parts | C-0100,,C-0100-VC |
---|
ImageSize | 100 |
---|
ShowDesc2 | true |
---|
ShowImage | true |
---|
isMissingRequiredParameters | true |
---|
ShowDesc1 | true |
---|
SingleRow | true |
---|
|
Programming Steps
Identify desired unit address for card reader.
Set dip switches in combination to equal the unit address value. See below for an explanation of dip switching. Dip Switch Cheat Sheet
Image Added
Dip Switch Values
Each switch has a value associated with it, as shown in the table below. Turning switches ON causes their values to be added together.
Switch 1 | Switch 2 | Switch 3 | Switch 4 | Switch 5 | Switch 6 | Switch 7 | Switch 8 |
---|
128 | 64 | 32 | 16 | 8 | 4 | 2 | 1 |
For example turning switch numbers 8 (1) and 7 (2) on represents the value of 3, or turning on switch numbers 4 (16), 6 (4), and 8 (1) equals 21. Using this binary chart you can achieve any number between 1 and 255.
Expand |
---|
title | Program Card Programming |
---|
|
Needed Bw part list |
---|
Parts | C-2PROGRAM,C-0101,C-0102,C-0103 |
---|
ImageSize | 100 |
---|
ShowDesc2 | true |
---|
ShowImage | true |
---|
isMissingRequiredParameters | true |
---|
ShowDesc1 | true |
---|
SingleRow | true |
---|
|
Programming StepsIdentify desired unit address for card reader. Power cycle card reader. Insert Program card, reader will display:
Set Address: 0**
Dip Card to Set To increase current digit: Insert tip of card and remove quickly. To move to next digit: Insert card fully and wait (approx 2 seconds). After accepting last digit of unit address, reader will display:
Storing Value
Remove Card Now
Video Tutorial |