To configure more than 254 machines some special steps must be taken.
With the exception of Point-Of-Sale (POS) systems being set to Machine ID 350, a specific series of steps are
Note |
---|
Warning |
IMPORTANT The maximum wired (WCRD) machine limit is 320. Configuring a Wired LaundryCard machine number past 320 will cause WCRD to show the entire line as UNDEFINED. The maximum wireless reader machine limit is 999. |
Updating CCI.INI for All X-Changers
To allow selecting a machine number above 254 in the LaundryCard GUI, CCI.ini must be updated on all X-Changers..
Open
D:\CCI\Process_Initialization\CCI.ini
Open the CCI.ini file for every X-Changer for editing.in a text editor.In the
[STATE_MACHINE]
section add the following lineMAX_MACHINE_ID=###
where ### is any number between 255 and 320.MAX_MACHINE_ID=###
Example:
Save the file and repeat this process for every X-Changer.
The Machine Config screen will now show numbers up the value specified in CCI.ini.
Reader Addressing
...