Install Mounting Hardware
cci-readerinstall-kit |
---|
KitID | 584 |
---|
KitDesc | Coin and Card |
---|
|
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F2 FasCard Reader Mounting Guide for further instructions.
...
cci-readerinstall-kitstep |
---|
|
Connect the C-6204-40 Power Adapter Harness (12VDC power) to the H10 connection on the Machine Control Assembly. Secure the green wire beneath the ground screw.
|
Connect Coin Sense Harness
cci-readerinstall-kit |
---|
KitID | 700 |
---|
KitDesc | Coin Drop: Factory |
---|
|
Disconnect the coin drop from the machine control assembly. Connect the C-6250 Coin Sense Harness to the harness connected to the coin drop.
|
Connect Machine Interface Harness
cci-readerinstall-kitstep |
---|
KitID | 582 |
---|
KitDesc | Pulse and Serial |
---|
|
Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly. |
|
Machine Configuration
ACA machines using a serial configuration require dip switch 3 on the Machine Control Board to be set to the 'ON' position. Leave all other dip switches as is.
Multiexcerpt include |
---|
SpaceWithExcerpt | com.atlassian.confluence.content.render.xhtml.model.resource.identifiers.SpaceResourceIdentifier@7627108f |
---|
MultiExcerptName | ACA Configuration |
---|
PageWithExcerpt | _Machine Configuration |
---|
|