Install Mounting Hardware
cci-readerinstall-kit |
---|
KitID | 616 |
---|
KitDesc | Coin and Card |
---|
|
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.step |
---|
|
|
cci-readerinstall-kit |
---|
KitID | 813 |
---|
KitDesc | Card Only - Coin Ready |
---|
|
Remove coin box and coin slide. Install C-5771 Metercase Bracket and secure using C-0303 Topload Mounting Bolt.
|
Cci readerinstall kit |
---|
KitID | 905 |
---|
KitDesc | Card Only - Card Ready |
---|
|
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
Cci readerinstall kit |
---|
KitID | 614 |
---|
KitDesc | Coin Model |
---|
|
Remove coin box and coin slide. Install C-5771 Metercase Bracket into the front opening of the metercase and secure using C-0303 Topload Mounting Bolt from the inside. After running the Cat5e cables and start harness through the front opening of the metercase bracket and connecting them to the LaundryCard reader, use the (2) C-0141 8-32 x 1-1/2" Socket Screws to secure the reader. Apply the C-0015 Label to the front of the LaundryCard reader around the card slot.
|
Cci readerinstall kit |
---|
KitID | 755 |
---|
KitDesc | Card Model |
---|
|
Use the C-0930 Mounting Bracket to mark out the center opening for the card reader and the lower set of holes to the left and right of the central opening. Ensure the positing leaves enough space for the reader's bezel to sit flat against the machine's panel and for the reader to be inserted into the machine and allow for the CAT5 cables to be connected.
Cut out the central opening and use a 9/64" Drill Bit to make a hole at each drill marks to the left and right of the central opening. Place the C-0930 Mounting Bracket on the inside of the machine's panel. Pass through and connect the CAT5 cables and machine start harness to the reader. Use the (2) C-0144 8-32 x 2" Flat Screw to attach the reader to the C-0930 Mounting Bracket. Apply C-0015 Label over the area around the card slot on the front of the LaundryCard reader.
|
...
KitID | 584 |
---|
KitDesc | Coin and Card |
---|
...
Place the C-6700-TEMP Drill Template on the desired mounting location.
...
Verify included harnesses will reach desired location without encountering interference from internal machine components.
...
KitID | 860 |
---|
KitDesc | Card Only - Coin Model |
---|
...
Remove existing coin box and coin mechanism.
...
Run reader harnesses through the metercase and out the opening where the coin mechanism was mounted.
...
Insert the reader harnesses through the hole in the C-6911 Metercase Bracket and then insert the bracket into the metercase opening.
...
Secure the C-6911 Metercase Bracket to the metercase using the C-0301 Mounting Bolt.
...
KitID | 998 |
---|
KitDesc | Card Only - Card Model |
---|
...
Connect Power
Connect Coin Sense Harness
Cci readerinstall kit |
---|
KitID | 721 |
---|
KitDesc | Coin Drop - Factory Optical |
---|
|
Disconnect the Coin Drop from the Machine Control Assembly. Connect the C-6362 Coin Sense Harness to the harness connected to the Coin Drop.
|
Cci readerinstall kit |
---|
KitID | 693 |
---|
KitDesc | Coin Drop: Factory |
---|
|
Disconnect the Coin Drop from the Machine Control Assembly. Connect the C-5362 Coin Sense Harness to the harness connected to the Coin Drop.
|
Connect Machine Interface Harness
...
KitID | 590 |
---|
KitDesc | Pulse/Serial - Debit (AA3) Connection |
---|
...
Connect and Mount Reader
...
Machine Configuration
Multiexcerpt include |
---|
SpaceWithExcerpt | CCIDOC |
---|
MultiExcerptName | MayTag Gen1 MLV+ Pulse |
---|
PageWithExcerpt | _Machine Configuration |
---|
|
...