cci-readerinstall-kit |
---|
KitID | 791 |
---|
KitDesc | Card Only - 10 Degree Front Panel Coin Drop Models |
---|
|
Remove existing coin box and coin drop. Remove connections to coin vault service switch and bridge connections using C-5365 Bypass Harness. Install C-5765-W Metercase Bracket over the front of the metercase and secure using the C-1059 Kep Nut, and C-1070-W Washer.
|
Cci readerinstall kit |
---|
KitID | 857 |
---|
KitDesc | Card Only - 10° Panel Coin Model |
---|
|
Remove existing coin box and coin drop.
Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
Attach the C-5414 F2 Mounting Bracket to the C-6765-W-R1 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.
Run any card reader harnesses through the coin slot openings and the circular hole in the C-6765-W-R1Metercase Bracket.Install the C-6765-W-R1 Metercase Bracket so that the two threaded posts insert into the coin drop slots. Then secure it to the machine using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.
...
...
...
...