3552 Reader Install Guide
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
Item No. | Component | Notes |
1 | Power Connection Port | Utilizes the same power harnesses as the first generation FasCard reader. |
2 | Pulse Connection Port | Connection point for pulse machine start harnesses. |
3 | Coin 1 Connection Port | This is the connection point for the harness input associated with Coin 1. |
4 | Coin 2 Connection Port | This is the connection point for the harness input associated with Coin 2. |
5 | Serial Connection Port | This is the connection point for serial machine start harnesses. |
Feed remaining harness ends through mounting hole as described in F2/F3 FasCard Reader Mounting Guide.
Connect the free end of the C-5240 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin 1 Sense Harness Connection Port) as shown in the image above.
Connect the free end of the C-6204-40 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.
Connect FasCard reader to base as described in the F2/F3 FasCard Reader Mounting Guide.
Machine Configuration
ACA machines using a serial configuration require dip switch 3 on the Machine Control Board to be set to the 'ON' position. Leave all other dip switches as is.