1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.

    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.

  2. Connect the C-5360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

  1. Disconnect the terminal quick connects from the terminal block mounted on top of the coin vault.

    1. Mark the outer green and red quick connects for later use if using C-5265 Machine Start Harness.

  2. Connect the C-6360 Coin Sense Harness to the terminal block tabs. Match each connection by color of the coin sensor wires.

Machine Configuration

Singlevend - Coin Pulse

  1. Enter the machine's System Menu and set the following settings (See machine programming manual for more info.)

    1. Machine Settings

      1. Liquid Soap Supply: Enabled

    2. Payment Settings:

      1. Enable Types: Disable all payment types

      2. Coin Options: Single

      3. Coin 1 Value: Intended Vend Price

      4. Coin 2 Value: Intended Vend Price

      5. Serial Payment System: Disabled

  2. On the FasCard Admin site, create a SingleVend equipment type with the following settings:

    1. Mode: Simple

    2. Pulse Length: 1000

    3. Pulse Interval: 250

    4. Pulse Type: Relay

    5. Sensor Input: Required Off

    6. Show Remaining Time: Disabled

    7. Cycle Time: 600 Seconds

    8. # Pulses: 1