0404 Reader Install Guide

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer
Manufacturer: Laundrylux
Make: Wascomat
Model Length: 4

Non-Compass/Compass Pro Control

For Set-O-Matic drop, set Dip Switch 7 to ON (?)

Associated Models


W620
W630
W640
W645
W650
W655
W675

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Connect Power

 I-P0008

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 3

Part #: C-5210

Desc 1: Power Adapter Harness

Desc 2: CGI

   Qty: 1

Part #: C-5500-84

Desc 1: Power Extension Harness

Desc 2: 84"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.

  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.

  3. Connect the C-5500-84 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

CCI Software Configuration

Machine ControlPulseSerial
Compass (Gen6)SingleVend (Relay) / 42msLaundrylux Compass Washer
Compass Pro (Gen7)SingleVend (Relay) / 42msmsLaundrylux Compass Pro Washer
Keltner - PulseSingleVend (Relay) / 1000ms*NOT SUPPORTED*
Rotary Timer - PulseSingleVend (Relay) / 2000ms*NOT SUPPORTED*
Set-O-Matic - PulseSingleVend (Relay) / 100ms*NOT SUPPORTED*