Place the C-6700-TEMPDrill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to Touchscreen Reader Mounting Guide (F2 & F3)for further instructions.
Cci readerinstall kit
Card Only - Card Ready
Place the C-6700-TEMPDrill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to for further instructions.
Optional: Apply C-5035 Label over card slot.
Connect Power
Cci readerinstall kit
KitID
595
Tap power as described in the Fascard Reader Install - Universal Conceptsdocument by connecting the C-5210 Power Adapter Harness to the incoming power wires.
120vac: Tap and connect the blue wire to L1 and the brown wire to N.
240vac: Tap and connect the brown and blue wires to connectors L1 and L2 wires.
Tap and connect the green wire to the ground wire.
Connect the opposite end of the C-5210 Power Adapter Harness to the C-5602 Power Converter.
Connect the C-5500Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
Cci readerinstall kit
KitID
700
KitDesc
Coin Drop: Factory
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
Cci readerinstall kit
KitID
642
KitDesc
Pulse
Connect the C-5272 Machine Start Harness to the Coin 1 connector in the metercase.
Cci readerinstall kit
KitID
643
KitDesc
Serial
Connect the C-5274R1 Machine Start Harness to the Serial Communication Harness behind the control panel.
Connect and Mount Reader
Multiexcerpt include
SpaceWithExcerpt
CCIDOC
MultiExcerptName
F2 Reader
PageWithExcerpt
_Reader Ports
...
For pulse start harnesses (white connector), connect to port 2 (Pulse Connection Port) as shown in the image above.
For serial start harnesses (black connector), connect to port 5 (Serial Connection Port) as shown in the image above.