Overview
Equipment Details
Type: Washer
Manufacturer: LG
Make: LG
Model Length: Not Set
Titan-C Washer
Coin/Pulse support only at this time
Associated Models
TCW2013CS1
TCW2013CS3
TCW2013LS1
TCW2013QS1
TCWM2013CD3
TCWM2013CS3
TCWM2013QS3
Installation
Install Mounting Hardware
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to Touchscreen Reader Mounting Guide (F2 & F3) for further instructions.
Connect Power
I-P0003
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5210 Power Adapter Harness to the incoming power wires.
120vac: Tap and connect the blue wire to L1 and the brown wire to N.
240vac: Tap and connect the brown and blue wires to connectors L1 and L2 wires.
Tap and connect the green wire to the ground wire.
Connect the opposite end of the C-5210 Power Adapter Harness to the C-5602 Power Converter.
Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0027
Part #: C-6250
Desc 1: Coin Sense Harness
Desc 2: F2
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
I-T0046
Part #: C-5272
Desc 1: Machine Start Harness
Desc 2: LG
Qty: 1
Connect the C-5272 Machine Start Harness to the Coin 1 connector in the metercase.
I-T0047
Part #: C-5274R1
Desc 1: Machine Start Harness
Desc 2: LG
Qty: 1
Connect the C-5274R1 Machine Start Harness to the Serial Communication Harness behind the control panel.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Titan-C - Washer | SingleVend (Relay) / 30ms | LG Giant-C Plus/Titan Washer |
Titan-C Max - WiFi 2.0 Washer | SingleVend (Relay) / 30ms | *NOT SUPPORTED* |