Cci readerinstall kit
KitID584
KitDescCoin and Card
  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Cci readerinstall kit
KitID857
KitDescCard Only - 10° Panel Coin Models
  1. Remove existing coin box and coin drop.

  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.

  3. Attach the C-5414 F2 Mounting Bracket to the C-6765-W-R1 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.

  4. Run any card reader harnesses through the coin slot openings and the circular hole in the C-6765-W-R1Metercase Bracket.

  5. Install the C-6765-W-R1 Metercase Bracket so that the two threaded posts insert into the coin drop slots. Then secure it to the machine using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.

  • Remove existing coin box and coin drop.

  • Install theC-5365 Bypass Harnessby removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.Bend the tabs outward and insert theC-0940 Vault Cover in to the coin vault opening.
  • Apply the C-5035 Label over the opening for the coin drop.
  • Place theC-6700-TEMPDrill Template on the desired mounting location.
  • Verify included harnesses will reach desired location without encountering interference from internal machine components.

  • Refer to for further instructions.
    Cci readerinstall kit
    KitID911
    KitDescCard Only - Flat Front Panel Coin Models
    Cci readerinstall kit
    KitID906
    KitDescCard Only - Card Models
    1. Place the C-6700-TEMP Drill Template on the desired mounting location.

    2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

    3. Refer to FasCard Mounting Guide for further instructions.

    Connect Power

    Cci readerinstall kit
    KitID581
    KitDescACA Controls
    1. Connect the C-6204-40 12VDC Power Harness to the H10 connection on the Machine Control Assembly.

      1. Connect the green wire to a chassis ground.

    2. The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.

    Cci readerinstall kit
    KitID837
    KitDescTitanium Controls
    1. Connect the 2-pin connector from the C-6207 F2, ACA Power Harness to the 24v transformer behind the front control panel.

    2. The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.

    Cci readerinstall kit
    KitID794
    KitDescACA Controls with Electronic Coin Drops
    1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.

    2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602R1 Power Converter.

    3. Connect the C-5500-84 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.

    Connect Coin Sense Harness

    Cci readerinstall kit
    KitID700
    KitDescFactory Optical Coin Drop
    1. Disconnect the Coin Drop from the Machine Control Assembly.

    2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

    Connect Machine Interface Harness

    Cci readerinstall kit
    KitID648
    KitDescPulse - Coin
    1. Connect the C-5300-NC Machine Start Harness to the coin 1 connector on the Machine Control Assembly.

    Cci readerinstall kit
    KitID582
    KitDescSerial Communication / Serial Pulse
    1. Connect the C-5240 Machine Start Harness to the the H3 connection on the Machine Control Assembly or Communication board.

    Connect and Mount Reader

    Multiexcerpt include
    SpaceWithExcerptCCIDOC
    MultiExcerptNameF2 Reader
    PageWithExcerpt_Reader Ports

    1. Feed remaining harness ends through the mounting hole.

    2. (Pulse - Coin Only) If using the C-5300-NC Machine Start Harness, connect the free end to port 2 (Pulse Connection Port) as shown in the image above.

    3. (Serial Comm Only) If using the C-5240 Machine Start Harness, connect the free end to port 5 (Serial Connection Port) as shown in the image above.

    4. (Coin and Card Installations Only) Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    5. Connect the free end of the C-6204-40, C-6207, or C-5500-84 Power Harness to port 1 (Power Harness Connection Port) as shown in the image above.

    Machine Configuration