Cci readerinstall kit | ||||
---|---|---|---|---|
| ||||
Optional: Remove existing payment device and cover opening usingC-0939BNA Cover Plate.Place theC-6700-TEMPDrill Template on the desired mounting location.IfC-0939 BNA Cover Plateis used, drilling mounting holes into the plate is recommended. Verify included harnesses will reach desired location without encountering interference from internal machine components.
| ||||
Cci readerinstall kit | ||||
| ||||
|
Connect Power
Power is supplied through the same Machine Interface Harness described in step 4.
Connect Coin Sense Harness
Not applicable in this setup. FasCard reader does not collect payment from any other devices, and will only send funds to the machine's control.
Connect Machine Interface Harness
Cci readerinstall kit | ||||
---|---|---|---|---|
| ||||
|
Connect and Mount Reader
Feed remaining harness ends through the mounting hole as described in the F2 Reader Mounting Guide.
Connect the black, 10-pin connection of the C-6124-MDB Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
Connect the clear, 3-pin connection of the C-6124-MDB Power Harness to port 1.
Secure the FasCard reader to base as described in the F2 Reader Mounting Guide.
Cci readerinstall footer |
---|