Skip to end of banner
Go to start of banner

3429 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

ERROR: Unable to connect to 'InstallRef' database.

Source: Microsoft OLE DB Driver for SQL Server
Number: -2147467259
Description: Cannot open database "CCI_InstallRef" requested by the login. The login failed.

Install Mounting Hardware

 I-M0174

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0178

Part #: C-0939

Desc 1: Bill Acceptor Cover

Desc 2:

   Qty: 1

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Optional: Remove existing payment device and cover opening using C-0939 BNA Cover Plate.

  2. Place the C-6700-TEMP Drill Template on the desired mounting location.

    1. If C-0939 BNA Cover Plate is used, drilling mounting holes into the plate is recommended.
  3. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  4. Refer to F2 Reader Mounting Guide for further instructions.

Connect Power

Power is supplied through the same Machine Interface Harness described in step 4.

Connect Coin Sense Harness

Not applicable in this setup. FasCard reader does not collect payment from any other devices, and will only send funds to the machine's control.

Connect Machine Interface Harness

 I-C0020

Part #: C-6124-MDB

Desc 1: Machine Start Harness

Desc 2: F2 MDB Interface Harness

   Qty: 1

  1. Connect the C-6124-MDB Machine Start Harness to the MDB connection on the Machine Control Assembly.
    1. Optional: Use the short pigtail MDB connection to reconnect any other payment devices still in use.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole as described in the F2 Reader Mounting Guide.
  2. Connect the black, 10-pin connection of the C-6124-MDB Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
  3. Connect the clear, 3-pin connection of the C-6124-MDB Power Harness to port 1.
  4. Secure the FasCard reader to base as described in the F2 Reader Mounting Guide.
ERROR: Unable to connect to 'InstallRef' database.

Source: Microsoft OLE DB Driver for SQL Server
Number: -2147467259
Description: Cannot open database "CCI_InstallRef" requested by the login. The login failed.
  • No labels