Overview

This page is intended to guide the user through removal and replacement of the X-Changer Bill Note Acceptor for LaundryCard systems. Table of ContentsmaxLevel2minLevel2MEI AE2600 Series and MEI Talos bill note acceptors.

Multiexcerpt include
MultiExcerptNameWarning
DisableCachingtrue
PageWithExcerptCCIDOC:_General

Required Hardware

Ui text box
sizemedium
typenote

Bill note acceptors vary across cabinet types and may not offer cross-compatibility.

Please contact Technical Support before ordering a replacement bill note acceptor (BNA) to ensure you obtain the correct model for your machine. Bill note acceptors vary across X-Changer types and cannot be mounted universally

For Pyramid Bill Note Acceptor Replacement, Click Here .


Bw part list
PartsC-1002,C-1004,C-1004-V2,C-5660,C-5820
SizingModeHeightShowDesc3false
SingleRowtrue

Recommended Tools and Supplies (Not Included)

Required Tools
Phillips head screwdriver

Image RemovedImage Added

Socket wrench

Socket: 11/32"

Image RemovedImage Added

Installation

...

Table excerpt
nameBNAinstall

Step 1 - Remove Bill Cassette

...

  1. Open the front door of the

...

  1. cabinet.
  2. Remove the bill cassette from the bill note acceptor.

...

panel

Step 2 - Disconnect BNA Power and Data

...

  1. Disconnect the power and

...

  1. communication harnesses connected to the right side of the bill note acceptor.
    1. Use caution - do not pull on the wires as doing so with sufficient force may

...

    1. detach them from the connector.

...

panel

Step 3 - Remove BNA from Cabinet Door

...

  1. Locate and remove the four (4) 11/32" kep nuts (outlined in red).
    1. On the C-1002 model (V1

...

    1. X-Changer Cabinets) one nut is located on each side of the BNA and two are located near the top.
    2. On

...

    1. C-1004, C-1004

...

    1. -V2, C-5660, and C-5820 models (V2 X-Changer Cabinets, Add Value Kiosks, and Touch Kiosks) one nut is located on each side of the BNA and two are located near the bottom.

...

panel

Step 4 - Install New BNA

...

...

  1. Install the new bill note acceptor into the opening created by removing the previous acceptor.
  2. Reverse the

...

  1. preceding steps to install.
    1. Tighten kep nuts in appropriate locations.
    2. Connect power and

...

    1. communication harnesses as previously connected:

      1. C-1004-V2 Talos BNAs in V2 X-Changer Cabinets use the exact same power and communication harnesses as the MEI Legacy 2000 BNAs typically found in a non-Pyramid X-Changer build:
        • C-1003 BNA Serial Interface cable.
        • C-1037R1 BNA Power Cable V2.
        • C-1004-CBL Stock BNA Cable for connecting the C-1037R1 BNA Power Cable to the Power port on the bill acceptor.

      2. If using a Talos BNA in an Add Value Kiosk, ensure the newer C-5690R2 communication harness is being utilized. The legacy C-5690 interface harness is incompatible with Talos BNAs.

      3. If using the C-1004-V2 Talos BNA in a Touch Kiosk, the C-5660-110P BNA Power Cable is required. The 9-pin 24v connector on the Touch Kiosk Power Controller will not be able to power the C-1004-V2 Talos BNA.

    2. Attach bill cassette.

Powering C-1004-V2 Talos BNAs in a Touch Kiosk

...

Unlike the legacy C-5660 MEI BNA and C-5660-V2 Talos BNA that utilize the 9-pin 24v port on the Power Controller, the C-1004-V2 Talos BNA has a 110vac power requirement. The C-5660-110P BNA Power Cable is specifically designed to power the C-1004-V2 Talos BNA within a Touch Kiosk by drawing power directly from the power supply's Load (L) and Neutral (N) terminals.

110ptruepage

Additional Resources