Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Multiexcerpt
MultiExcerptNameCenturion Quantum Gold (C4) - TLW

Centurion Quantum Gold TLW Controls

  1. Power off the machine.
  2. Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.
  3. Power on the machine.
Multiexcerpt
MultiExcerptNameTitanium Configuration (Small Dryer)

Titanium Controls (11th character in the model number is 6.) 

  1. Enter Manual Mode by opening the service door and closing the coin vault switch. Then press the following two buttons based on the control:

    Quantum Gold Pro (T4)

    Galaxy 600 Pro (T2)

    MDC II (T1)

    High Temp & Med TempHigh Temp & Med Temp

    High Temp & Med Temp

  2. rAPid will be displayed on the control. Select the Prog option and then configure the following settings:
    1. Serial Payment Configuration (SErPAY): Card
    2. Card Enable (CArdEn): On
  3. Exit Manual Mode.

...