Panel |
---|
| Card Dispenser Replacement Guide Ui step |
---|
- Unplug the power cable from the card dispenser (shown in red).
- Empty the card hopper (shown in yellow).
|
|
Panel |
---|
| Ui step |
---|
- Remove the bill magazine from the bill validator (located below the card dispenser).
|
|
Panel |
---|
| Ui step |
---|
- Locate the four (4) Phillips head screws on the bottom of the card dispenser tray, located above the bill validator.
- Remove all four screws and washers. These will be used to attach the new dispenser.
- Existing dispenser can now be removed.
|
|
Panel |
---|
| Ui step |
---|
- Remove the card dispenser guide (part no. C-0993) from the front of the card dispenser being replaced.
- Attach the card dispenser guide to the new card dispenser being installed. Do not over tighten screws- leave play for final adjustments once installed in X-Changer cabinet.
|
|
Panel |
---|
| Ui step |
---|
- Install new card dispenser by performing step 3 in reverse. Do not over tighten- leave play for final adjustments.
- Align card dispenser such that the dispenser guide tray is flush with the door slot.
- Once guide tray is properly positioned, tighten screws on guide tray.
- Tighten dispenser tray screws.
- Reconnect bill validator magazine.
- Reconnect power cable disconnected in step 1.
|
|
|