Comment: Updated certain sections of document to coincide with upcoming install vids.
Div
Classtoc-header
Section
Column
width30
Panel
titleOn this Page

Table of Contents
maxLevel3
minLevel2

Column
width70
Panel
titleOverview

This document explains the differences between Single-vendSingleVend/Pulse and Multi-vendMultiV/Serial communications as well as demonstrates the basic principles involved when installing a FasCard reader. It is not intended to serve as a guide for any specific machine installation.

Ui text box
sizemedium
typewarning

CCI takes no responsibility for the accuracy of this document or for any damage that may occur if using this document to guide installation or maintenance of a FasCard system.

Ui text box
sizemedium
typewarning

When changing the firmware on a machine with a multi-vend / Serial connected reader, disconnect the reader during the firmware update process.

...

Regardless of the specific qualities of the machine on which you are installing a FasCard reader, some basic aspects are universal.  At minimum, the FasCard reader requires a connection to its power supply as well as the control board of the machine on which it is being installed, while many installations also utilize a coin drop for maximum versatility.  Typical configurations for coin and card setup are shown below, in configurations using a serial or pulse harness.  Fig. 1a refers to the connection positions on the F1: FasCard Wireless Reader and Figfig. 1b refers to connection positions on on F2: FasCard Touchscreen Reader.  For card-only installations, omit the coin drop.  These connections are shown generically as the harnesses for each type of drop and machine board may vary widely (examples of various harnesses are found throughout this document).

...

Connecting your FasCard reader to the control board of the machine requires a specific wire harness based upon your machine and the type of start mechanism employed.  Two different types of harness are utilized in FasCard installations depending upon the capabilities of the machine-  these - these are referred to as Single-vend SingleVend (also known as Pulse) or Multi -vend Level Vend (also known as Serial, or MLV/MultiVend).  Understanding the difference between the types of harness harnesses is vital to understanding the capabilities of the system once installed.  More on these harnesses and control types can be found below under the heading headings "Understanding Single-vend and Multi-vend SingleVend and MultiVend Control Types".  

Figure 2a (below) illustrates and labels the various connections on the reverse of the FasCard reader.  

...

  • Connecting the opposite end of the harness varies by board type, but in general a Single-vend/Pulse connection will connect where the coin drop was previously connected.  Multi-vend/Serial connections typically connect to a specific serial port on the board, which will also vary by machine.
  • Connecting a coin drop may require a coin sense harness to adapt the native connection.  This will be included in your installation kit if needed (see Fig. 2b, above).
  • Connecting the power supply utilizes a harness provided with your reader.  Power considerations are further discussed below under the heading "Tapping Power".

...

SingleVend Pulse

...

vs. Multi

...

Level Vend (Serial/MLV Control)

The FasCard system utilizes two different methods for starting machines/performing vends.  Both methods function differently and not all methods are necessarily available for all machine types.  Both methods are discussed below in separate sections. Some machines are capable of utilizing either Single-vend or Multi-vendSingleVend or MultiVend, but only one control type can be used at any given time.

Understanding the

...

SingleVend/Pulse Control

...

Type 
Anchor
SLV
SLV

A Single-Vend or Pulse configuration effectively emulates a coin drop by sending an electrical pulse to the machine that serves as the "Start" signal.  This is the simplest method of starting the machine and can be used across the widest variety of systems and is sometimes adapted for less obvious functions (controlling an electric door lock, for example).  It is important to note that when using a pulse configuration, the FasCard reader has no direct communication to the machine control board and is capable only of sending the electrical pulse used as the "Start" signal.  This means that the card reader itself does not receive any information from the machine regarding cycle times, add-ons, or otherwise.  Settings related to the length, duration, and number of pulses can be setup on the FasCard Admin website (https://admin.fascard.com/).

...

  • A single-vend harness will always connect to the FasCard reader on the connection labeled "C" in Figure 2a, above.
  • The board-side end of the harness will vary by machine/connection type.  
  • More information on Single-vend start methods and configurations is available here: Configuring SingleVend.

Understanding the

...

MultiVend/Serial Control

...

Type 
Anchor
MLV
MLV

A Multi-vend or Serial configuration differs from the Single-vend SingleVend type in significant ways.  The Multi-vend MultiVend connection allows direct communication with the control board that it is connected to, sometimes allowing a much wider variety of options and affording greater versatility than the Single-vend SingleVend control type.  Rather than simply emulating a coin drop and sending an electrical "Start" signal, the Multi-vend control type exchanges information with the machine control board.  Depending upon the capabilities of the machine, this can provide greater control and flexibility of vend prices as well as allow certain machine settings to be controlled directly from the FasCard Admin website (https://admin.fascard.com/).  

...

Power is supplied to the FasCard reader by tapping into the existing electrical wiring in the machine onto which it is being installed.  The power adapter supplied with your installation kit (part no. C-5602) can convert 120 or 240 volts for use by the FasCard reader.  Hot, neutral, and ground wires will all be tapped during installation. If the machine uses twin 120 volt lines, only one needs to be tapped to power the FasCard reader, but a single 240 can also be tapped if necessary.  Power can be tapped in different places depending upon the machine. It may be necessary to consult the documentation or manufacturer of the machine to verify wiring.

An example Some examples of the spade taps (fig. 5a) used to tap power is shown in Fig. 5a below.  Fig. 5b is an example of the harness power, power adapter harnesses connected to said taps .  Fig. 5c shows the power supply itself.  Image RemovedImage RemovedImage Removed(fig. 5b), and power converters (fig. 5c) are as follows

Image Added

Image Added

Image Added

Image Added

Image Added

Image Added

Figure 5a: Spade TapsFigure 5b: Power Adapter HarnessesFigure 5c: Power Converters
  • Once power is correctly tapped and all harnesses connected, the FasCard reader will power on when the machine is powered on.
  • Power harnesses may vary depending upon machine type. 
  • Power is connected to the FasCard reader at connection "D" shown in Figure figs. 1a and 1b, above.

Connection Process

Note
titleIMPORTANT

The following is just one possible example of how power may be provided to a FasCard/FLEX reader. While universal power principles apply, installation may vary based on machine.

  1. Locate the 110vac power leads.Connect the FasCard AC Power Harness leads with wire taps. White and black wires power terminal housing the power leads. In most cases, this can be identified by the way the terminal is labeled (L1, L2, N, etc.)
  2. Attach the necessary spade taps for power application:
    Image Added
    1. In this example, 1st Hot (L1) and 2nd Hot/Neutral (L2/N) power connections are labeled.
      Image Added

    2. In some instances, the different line wires (typically black for Hot, white for Neutral, in a three-phase circuit) can be interchangeably connected to hot or neutral power connections
    ,
    1. .
    2. Green wire must be connected to ground. Depending on the kit/harness, this may be either through a third (ground) spade tap, or a ground terminal/lug:
      Image Added

  3. Connect the FasCard Power Adapter Harness leads to their respective spade taps. If the green (ground) wire was also tapped, ensure the green wire connects to the ground spade.
    Image Added
  4. (Also shown in step 3) Connect the opposite end of the FasCard AC Power Adapter Harness to the input side harness of the FasCard power supply.
  5. Connect the output harness of FasCard Power Supply Harness to the output side of the FasCard reader extension harnessPower Extension Harness.
    Connect extension to reader and secure Image Added

  6. Connect the 3-pin input end of the Power Extension harness to the power port on the FasCard/FLEX reader.
  7. Secure the power supply and any cabling inside the machine

    with

    as needed. Examples may include existing clips, zip ties, electrical tape, double-sided tape, etc.

    Image Added

    Image Added

Additional Information