Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Cci readerinstall header

Install Mounting Hardware

Cci readerinstall kit
KitID1013
KitDescCard unsafe-Only - Metercase Model
  1. Remove existing coin drop and coin box from the metercase.
  2. Install the C-0942 Metercase Bracket into the front of the metercase using the(2) C-1059 10-32 Keps Nuts.
  3. Run the Cat5 cables and C-5355 Machine Start Harness through the metercase and then through the rectangular opening in the C-0942 Metercase Bracket.

Connect Machine Interface Harness

Cci readerinstall kit
KitID658
KitDescSerial Communication Harness
  1. Connect the C-5355 Machine Start Harness to the CN4 Payment Device Connection located inside the metercase.

Connect and Mount Reader

Multiexcerpt include
SpaceWithExcerptCCIDOC
MultiExcerptNameLC Reader
PageWithExcerpt_Reader Ports

  1. Connect the free end of theC-5355 Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
  2. Connect the the Cat5 cables running to and from the adjacent machinesto ports labeled 3 (Line Connection Ports) as shown in the image above.
  3. Insert the reader into the C-0942 Metercase Bracket and secure using the (2) C-0141 8-32 x 1-1/2" Cap Screws and then cover using the C-0015 Label.

Machine Configuration

Multiexcerpt include macro
nameEncore - FLW
templateData[]
page_Machine Configuration
addpanelfalse

Cci readerinstall footer