Overview
This page is intended to guide the user through
...
the proper reboot and shutdown procedures for the CCI-provided computer stored within each X-Changer
...
Warning |
---|
Failure to follow the steps below when restarting X-Changer computers can lead to data loss. |
Determining the Primary System
...
Image Removed
...
Image Removed
...
Image Removed
...
cabinet. Each location may operate on a different version of LaundryCard, therefore a few screens may be different in the processes outlined below.
Determine the Primary system
It is imperative to know which X-Changer is labeled as the Primary. Failure to reboot the appropriately labeled X-Changer at the right time may result in data loss.
Warning |
---|
If both X-Changers are displayed as the database Primary or the database Backup, call CCI Technical Support immediately. |
Expand |
---|
title | Method 1 – LaundryCard main page |
---|
|
Version 6.5 and higher | Version 9 |
---|
LaundryCard software versions 6.5 and higher display Primary and Backup indicators in the upper left-hand corner of the screen when LaundryCard applications are running. |
|
...
Older software versions require different methods to obtain Primary and Backup information. | LaundryCard software version V9 displays the Primary in the center of the home screen when using a Manager, Attendant, or Technician card. |
|
...
Expand |
---|
title | Method 2 – Use the Store Status page to |
---|
|
...
Image Removed
...
determine the Primary system |
|
Insert a Manager, Attendant, or Technician card and navigate to the Store Status page. |
Ui tabs |
---|
Ui tab |
---|
| title | Reboot ProcedureVersion 5 and 6 | Version 7 and 8 | Version 9 |
---|
In V5 and V6, the Primary database will be in the 'Database' row. If CCI1 is listed here, that corresponds to X-Changer A. CCI2 corresponds to X-Changer B. | In V7 and V8, the Primary database is clearly labeled as such in the top row of the System Status section. |
---|
Tip |
---|
If both X-Changers are displayed as the Database Primary or the Database Backup, contact Technical Support. |
Reboot procedures
Expand |
---|
title | If the system to be rebooted is Database Backup |
---|
|
Frequency of Maintenance: Monthly Insert a Manager's card to (or a card with maintenance permissions) on the Backup X-Changer and click the Shutdown button.LaundryCard Versions 5 and 6: Select Reboot this Machine and click Go. Version 6: Do not uncheck Auto Start.LaundryCard Versions 7 and 8: Select the access the Maintenance menu. Press the Restart System button.
Image AddedChoose the appropriate button to reboot the chosen Backup X-Changer by letterClick OK when prompted.After the LaundryCard program closes, another prompt will appear to confirm restarting Windows. Click OK..
After this step is completed, the computer will shut down and restart. During this time, the Primary X-Changer may display a network connection error or experience a slow-down until the Backup X-Changer has restarted.
- Image Added
Windows will prompt for the confirmation of reboot. Click OK to confirm.
Image Added
|
Expand |
---|
title | If the system to be rebooted is Database Primary |
---|
|
- Using a manager or attendant card, verify that no database backup errors exist on the Check Messages page.
- Insert Manager's card to Primary X-Changer and click the Shutdown button.
LaundryCard Versions 5 and 6: Select Failover to Backup and click Go. Version 6: Do not uncheck Auto Start. | LaundryCard Versions 7 and 8: Select Failover to Backup. | After this step is completed, the computer will shut down and restart. During this time, the original Backup X-Changer will become the new Primary X-Changer and may display a network connection error or experience a slow-down until the original Backup X-Changer has restarted.
- Click OK when prompted.
- A database backup will be performed. Click OK when prompted by the completion notification.
- After the LaundryCard program closes, another prompt will appear to confirm restarting Windows. Click OK.
Ui tab |
---|
|
Required Hardware
USB KeyboardMouse or touch screenFrequency of Maintenance: Monthly
Insert a Manager's card (or a card with maintenance permissions) on the Primary X-Changer and access the Maintenance menu.
Press the System Error Messages button.
Image AddedVerify no database backup errors are present.
Image Added
If database backup errors are present, contact CCI Technical Support before proceeding.
Press the Back button.
Press the Restart System button.
Image AddedChoose Failover to Backup.
Image AddedKeepAGoin will display a popup indicating a database backup has been completed. Click OK to confirm.
Image AddedWindows will prompt for the confirmation of reboot. Click OK to confirm.
If you do not receive this prompt, go back to the Restart System menu and reboot the desired X-Changer.
Image Added
Shutdown procedures
Required hardware
USB keyboard
USB Mouse or touchscreen
Expand |
---|
title | If system to be shutdown is Database Backup |
---|
|
Instructions1. Connect Connect the keyboard to an available USB port on the computer and press the Windows key located along the bottom row.
2. Image Added
A Start menu will appear at the bottom left corner of the screen. Using the touch screen or a mouse, click Shut Down. 3. A
In version 9 you will need to press the power button, located on the bottom left corner of the Start menu. Version 7 | Version 8 | Version 9 |
---|
Image Added | Image Added | Image Added |
A window appears which allows log off, restart, or shut down. Select the desired option then click OK. Version 7 | Version 8 | Version 9 |
---|
Image Added | Image Added | Image Added |
Wait for the computer to shut down. All lights on the front of the computer should turn off and the monitor will go blank.
|
Expand |
---|
title | If system to be shutdown is Database Primary |
---|
|
- Using a manager or attendant card, verify that no database backup errors exist on the Check Messages page.
Insert Manager's card to Insert a Manager's card (or a card with maintenance permissions) on the Primary X-Changer and click the Shutdown button.LaundryCard Versions 5 and 6: Select Failover to Backup and click Go. Version 6: Do not uncheck Auto Start. | LaundryCard Versions 7 and 8: Select Failover to Backup. | After this step is completed, the computer will shut down and restart. During this time, the original Backup X-Changer will become the new Primary X-Changer and may display a network connection error or experience a slow-down until the original Backup X-Changer has restarted.
- Click OK when prompted.
- A database backup will be performed. Click OK when prompted by the completion notification.
- After the LaundryCard program closes, another prompt will appear to confirm restarting Windows. Click Cancel.
1. Connect access the Maintenance menu.
Press the System Error Messages button.
Image AddedVerify no database backup errors are present.
Image Added
If database backup errors are present, contact CCI Technical Support before proceeding.
Click the Back button.
Click the Restart System button.
Image AddedChoose Failover to Backup.
Image AddedKeepAGoin will display a popup indicating a database backup has been completed. Click OK to confirm.
Image AddedWindows will prompt for the confirmation of reboot. Click Cancel.
If this prompt does not populate, then proceed to step 10.
Image Added
Connect the keyboard to an available USB port on the computer and press the Windows key located along the bottom row.
Image Added
2. A Start menu will appear at the bottom left corner of the screen. Using the touch screen or a mouse, click Shut Down.
3. A In version 9 you will need to press the power button, located on the bottom left corner of the Start menu.
Version 7 | Version 8 | Version 9 |
---|
Image Added | Image Added | Image Added |
A window appears which allows log off, restart, or shut down. Select the desired option then click OK.
V7 | V8 | V9 |
---|
Image Added | Image Added | Image Added |
Wait for the computer to shut down. All lights on the front of the computer should turn off and the monitor will go blank.