cci-readerinstall-kit |
---|
KitID | 911 |
---|
KitDesc | Card Only - Coin Ready |
---|
|
Remove existing coin box.
Install theC-5365 Bypass Harnessby removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.Bend the side tabs of the C-0940 Vault Cover outward and install into the coin vault. The tabs should snap into place securing the bracket.
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to for further instructions. Cci readerinstall kit |
---|
KitID | 906 |
---|
KitDesc | Card Only - Card Ready |
---|
|
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to for further instructions.
...
...
...
Power off the machine.
Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.
Power on the machine.