Warning!
This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.
It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.
Overview
Equipment Details
Type: Stack Washer/Dryer
Manufacturer: Alliance
Make: [VARIES]
Model Length: 8
Associated Models
STET77WN
STGT79WN
Recommended Tools and Supplies
Drill
1 1/8" Tungsten Carbide Tipped Hole Cutter
Cutting Oil
9/64" Drill Bit
Center Punch
Hammer
Fine Point Permanent Marker
Pliers
Tape Measure
Installation
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
Item No. | Component | Notes |
1 | Power Connection Port | Utilizes the same power harnesses as the first generation FasCard reader. |
2 | Pulse Connection Port | Connection point for pulse machine start harnesses. |
3 | Coin 1 Connection Port | This is the connection point for the harness input associated with Coin 1. |
4 | Coin 2 Connection Port | This is the connection point for the harness input associated with Coin 2. |
5 | Serial Connection Port | This is the connection point for serial machine start harnesses. |
- Feed remaining harness ends through the mounting hole as described in the F2: FasCard Reader Mounting Guide.
- Connect the free end of the Machine Start Harness:
- If following steps for a serial Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
- If following steps for a pulse Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Extension Harness to port 4 (C-5500 Power Harness Connection Port) as shown in the image above.
- Secure the FasCard reader to base as described in the FasCard Mounting Guide.
Machine Configuration
- Power off the machine.
- Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.
- Power on the machine.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|---|---|
MDC (Vended) | SingleVend (MLV+) / 80ms | Alliance MDC Front Load Washer |
MDC (Vended) | SingleVend (MLV+) / 80ms | Alliance MDC Small Dryer |
NetMaster | SingleVend (Relay) / 80ms | *NOT SUPPORTED* |
NetMaster | SingleVend (Relay) / 80ms | *NOT SUPPORTED* |
Additional Resources
- How to Program Address on a FasCard Reader
- FasCard Admin Site - Equipment Setup
- FasCard Admin Site - Machine Setup
- FasCard Admin Site - Pricing & Features Schedule
- F1 Reader Mounting Guide
- FasCard F2/F3 Reader Installation Guide - Front Mount
- FasCard Installation Videos
- FasCard Kit Installations - Machine Configurations & Related Documents