V2 Cabinet Installationinstall-stepsINLINERequired Hardwarec-0103-b,C-2Programfalsefalse Step 1 - Disconnect Local Reader- Open the front door of the X-Changer cabinet and locate the rear of the local card reader.
- Disconnect the relay cable from the rear of the card reader.
- (Pull from the plastic connector - pulling on the wires may detach them from the connector.)
- Disconnect the Cat5 cable from the rear of the card reader.
Step 2 - Remove the Local Reader- With a utility knife or similar tool, carefully remove the 'Insert Card' decal surrounding the card slot.
- Remove the screws on the left and right edges of the card reader.
- This may require either the #2 phillips head or 11/32" hex driver - models may vary.
- Slide card reader forward and out of the mounting slot.
Step 3 - Install Replacement Readerc-0103-b,c-2programHeightfalsefalsetrue - Reverse the previous steps to install the new card reader.
- Insert reader into mounting slot.
- Mount with new or original screws.
- Reconnect 6 pin plastic connector to rear of card reader.
- Reconnect Cat5 cable to rear of card reader (ports are interchangeable).
- .
- Test card reader with existing customer or manager card to verify operation.
- If operation fails, contact Technical Support.
|