Connect the bare wire ends of the C-5313 Terminal Block to the Machine Control Assembly.Connect the C-5356 0111-RES Machine Start Harness to the Positions 2 and 3 on the terminal block. Terminal block positions connections are numbered 0-6 . Position 0 is closest to the board edgefrom the edge nearest the top of the board (position 0) to the bottom of the terminal block (position 6) For machines shipped before 1/1/2006, connect harness to positions 1 and 3. For machines shipped after 1/1/2006, connect harness to positions 3 and 5. For machines shipped near 6/1/2007, connect harness to positions 2 and 3. All other machines, connect harness to positions 3 and 4.
|