You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 4
Next »
Overview
Equipment Details
Type: Washer
Manufacturer: Maytag
Make: Maytag
Model Length: 8 to 10
Associated Models
MAT20PDA00
MAT20PDAWW
MAT20PDAWW1
MAT20PRAWW
MAT20PRAWW1
MAT20PRAYW
MAT23PDAWW
MAT23PDAWW0
MAT23PRAWW
Installation
Install Mounting Hardware
I-M0009
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-0301
Desc 1: Topload Mounting Bolt
Desc 2:
Qty: 1
Part #: C-0911
Desc 1: Metercase Bracket
Desc 2: Whirlpool - White
Qty: 1
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Remove coin box and coin slide.
Install C-5771 Metercase Bracket into the front opening of the metercase and secure using C-0303 Topload Mounting Bolt from the inside.
After running the Cat5e cables and start harness through the front opening of the metercase bracket and connecting them to the LaundryCard reader, use the (2) C-0141 8-32 x 1-1/2" Socket Screws to secure the reader.
Apply the C-0015 Label to the front of the LaundryCard reader around the card slot.
I-M0044
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Part #: C-0144
Desc 1: Screw
Desc 2: 8-32 x 2" - Flat
Qty: 2
Part #: C-0930
Desc 1: Mounting Bracket
Desc 2: Unimac/ADC
Qty: 1
Use the C-0930 Mounting Bracket to mark out the center opening for the card reader and the lower set of holes to the left and right of the central opening.
Ensure the positing leaves enough space for the reader's bezel to sit flat against the machine's panel and for the reader to be inserted into the machine and allow for the CAT5 cables to be connected.
Cut out the central opening and use a 9/64" Drill Bit to make a hole at each drill marks to the left and right of the central opening.
Place the C-0930 Mounting Bracket on the inside of the machine's panel. Pass through and connect the CAT5 cables and machine start harness to the reader.
Use the (2) C-0144 8-32 x 2" Flat Screw to attach the reader to the C-0930 Mounting Bracket.
Apply C-0015 Label over the area around the card slot on the front of the LaundryCard reader.
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0122
Part #: C-0303
Desc 1: Topload Mounting Bolt
Desc 2:
Qty: 1
Part #: C-6911
Desc 1: F2 Metercase Bracket
Desc 2: Whirlpool - White
Qty: 1
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Remove existing coin box and coin mechanism.
Run reader harnesses through the metercase and out the opening where the coin mechanism was mounted.
Attach the C-5414 Reader Bracket to the C-6911 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.
Insert the reader harnesses through the hole in the C-6911 Metercase Bracket and then insert the bracket into the metercase opening.
Secure the C-6911 Metercase Bracket to the metercase using the C-0301 Mounting Bolt.
I-M0187
Part #: C-6980
Desc 1: Maytag Bk Splash Mount
Desc 2: F2
Qty: 1
Part #: C-1042
Desc 1: Nut
Desc 2: 8-32 - Kep
Qty: 1
Part #: C-1070-W
Desc 1: Washer - Build: XCH
Desc 2: 1/4" x 1" O.D.
Qty: 1
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Remove the (4) Security T20 retaining screws from the front of the machine.
Lift up and pull panel forward and lay on machine. NOTE: The front panel may come apart, as it is two parts. Take care not to damage the ribbon cable.
Mount the C-6980 Mounting Bracket on the front of the panel so that the holes match on the right and the retaining screw on the back of the plate goes through the card slot.
Place the C-1070-W Washer and C-1042 Keps Nut onto the retaining screw and tighten using 11/32 socket to secure the mounting bracket. The bracket should feel slightly loose until the panel is reattached to the machine.
Connect Power
I-P0026
Part #: C-1098
Desc 1: 3M Dual Lock 1" wide
Desc 2: Use 4" strips for C-5602
Qty: 1
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Locate the 120v power lines in the machine. These wires are usually black and white and are located just inside the back of the panel. Use a voltage tester to confirm the correct wiring.
Apply the C-5101 Spade Taps to both the black and white power wires and clamping them down with pliers.
Plug the brown wire of the C-5336 Power Adapter Harness to the white/neutral wire tap and the blue wire to the black/L1 wire tap.
Locate a green chassis ground screw and loosen to insert the green wire from the C-5336 Power Adapter Harness and retighten.
Connect the 3-pin connector from the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.
Apply the C-1098 Velcro to the C-5602R1 Power Converter and secure inside the machine's panel.
Connect the 4-pin connector from the C-5500 Power Extension Harness to the C-5602R1 Power Converter.
Route the 3-pin connector from the C-5500 Power Extension Harness through the open card slot on the machine control panel.
Connect Coin Sense Harness
I-S0048
Part #: C-6362
Desc 1: Coin Sense Harness
Desc 2: MLG
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6362 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
I-T0004
Part #: C-5364
Desc 1: Machine Start Harness
Desc 2: Maytag MFR
Qty: 1
Locate the AA3 serial connection on the machine control board and plug in the C-5364 Machine Start Harness.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
MayTag AA3/Debit Connection Payment Pulse
Enter Service Mode by activating the service switch.
Locate Coin/Debit Option (J.) and set to Cd.
Enhanced Debit (Gen 2)
Enhanced Debit is self-selected when a Generation 2 card reader is installed in the dryer. The Ed option cannot be manually selected or deselected.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Gen2 | SingleVend (MLV+) / 24ms | Maytag Gen2 M17 Top-Load Washer |