Skip to end of banner
Go to start of banner

3581 Reader Install Guide

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Small Dryer (Single)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15

Associated Models


HDCBYRGS113CW01
HDEBCAGS173TW01
HDEBCRGS173TW01
HDEBCRGS175TW01
HDEBCRGS176TW01
HDEBYAGS173CW01
HDEBYAGS173TW01
HDEBYRGS116TW01
HDEBYRGS173TW01
HDESXRGS173TW01
HDGBCAGF116TW01
HDGBCAGS113TW01
HDGBCAGS116TW01
HDGBCASG116TW01
HDGBCRGF113TW01
HDGBCRGS113TW01
HDGBCRGS116EW01
HDGBCRGS116GW01
HDGBCRGS116TW01
HDGBYAGS113CW01
HDGBYAGS113TW01
HDGBYASP116TW01
HDGBYRGS1130T01
HDGBYRGS113TW01
HDGBYRGS116TW01
HDGSXRGS113TW01
HDSBYRGS116TW01
KDEBXRGS176TW01
KDESXAGS173YW01
KDESXRGS173TW01
KDGBXRGS115TW01
KDGBXRGS116TW01
KDNBXRGS173PW01
SDENCAGS1732W01
SDENCAGS173TW01
SDENCAGS176TW01
SDENCRGS173TW01
SDENCRGS173TW02
SDENCRGS176TW01
SDENXRGS173TW01
SDENYAGF173TW01
SDENYAGS103TW01
SDENYAGS116TW01
SDENYAGS153TW01
SDENYAGS1732W01
SDENYAGS173TW01
SDENYAGS176FW01
SDENYAGS176TW01
SDENYRGS173TW01
SDENYRGS176TW01
SDESXRGS173TW01
SDGNCAGS113TW01
SDGNCAGS116TW01
SDGNCAGS173PW01
SDGNCRGS113TW01
SDGNCRGS113TW02
SDGNCRGS116TW01
SDGNXRGS113TW02
SDGNXRGS116TW01
SDGNYAGS113TW01
SDGNYAGS116TW01
SDGNYRGF116TW01
SDGNYRGS113TW01
SDGNYRGS116TW01
SDGSXR2G113TW01
SDGSXRGF113EW01
SDGSXRGS113TW01
SDGSXRGS113TW02
SDGSXRSP115TW02

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0136

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place C-5763 TWL Bracket in the intended mounting location. Using the bracket, mark the location of all four mounting holes.
  2. Drill a hole at each marked location using a 3/16" drill bit.
  3. Attach C-5414 Mounting Bracket to the front of C-5763 using two C-5420 screws.
  4. Mount the C-5763 TLW Bracket using four C-5420 Screws and fasten from the inside of the panel.
 I-M0202

Part #: C-6762

Desc 1: Metercase Bracket

Desc 2: Coin Slide Ready Machine

   Qty: 1

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-0301

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

  1. Remove existing coin box and coin slide.

  2. Attach C-5414 Standard Bracket to the C-6762 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.

  3. Insert C-6762 Metercase Bracket into the metercase and secure using C-0301 Topload Mounting Bolt.
 I-M0123

Part #: C-1059

Desc 1: Nut

Desc 2: 10-32 - Kep

   Qty: 2

Part #: C-1070-W

Desc 1: Washer - Build: XCH

Desc 2: 1/4" x 1" O.D.

   Qty: 2

Part #: C-5760-A

Desc 1: Alliance Adapter Bracket

Desc 2: Mounts C-5760 to MeterCase

   Qty: 1

Part #: C-6762

Desc 1: Metercase Bracket

Desc 2: Coin Slide Ready Machine

   Qty: 1

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove the coin drop and coin box.
  2. Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.
  3. Secure C-5414 F2 Mounting Bracket to the C-6903 Mounting Bracket using the (2) C-5420 10-32 x 1/4 Pan Screws.
  4. Attach the C-5760-A Adapter Bracket to the C-6762 Mounting Bracket to the captured nut on the inside of the C-6762 Mounting Bracket.
  5. Run all reader harnesses through the metercase and out the opening where the coin drop normally mounts.
  6. Run all reader harnesses through the circular opening on the C-6762 Mounting Bracket.
  7. Install the C-6762 Mounting Bracket into the front opening of the metercase so the two threaded posts of the C-5760-A Adapter Bracket line up with the openings for the coin slots. Secure in place using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.
 I-M0119

Part #: C-1059

Desc 1: Nut

Desc 2: 10-32 - Kep

   Qty: 2

Part #: C-1070-W

Desc 1: Washer - Build: XCH

Desc 2: 1/4" x 1" O.D.

   Qty: 2

Part #: C-6765-W-R1

Desc 1: F2 Mounting Bracket

Desc 2: 10 Degree - White Finish

   Qty: 1

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove existing coin box and coin drop.

  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
  3. Attach the C-5414 F2 Mounting Bracket to the C-6765-W-R1 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.
  4. Run any card reader harnesses through the coin slot openings and the circular hole in the C-6765-W-R1 Metercase Bracket.
  5. Install the C-6765-W-R1 Metercase Bracket so that the two threaded posts insert into the coin drop slots. Then secure it to the machine using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.

Connect Power

 I-P0003

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 3

Part #: C-5210

Desc 1: Power Adapter Harness

Desc 2: CGI

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Use the C-5101 Spade Taps on the incoming power.
    1. Tap the L1 wire.
    2. Tap the N wire.
    3. Tap the Ground wire.
  2. Take the C-5210 Power Adapter Harness and connect the red tab connectors to the following wires:
    1. Connect the blue wire to the L1 wire.
    2. Connect the brown wire to the N wire.
    3. Connect the green/yellow wire to the Ground wire.
  3. Connect the 3-pin connector from the C-5210 Power Adapter Harness to the matching connection on the C-5602R1 Power Converter.
  4. Connect the 4-pin connector from the C-5602R1 Power Converter to the matching connection on the C-5500 Power Extension Harness.
 I-P0002

Part #: C-6204-40

Desc 1: Power Adapter Harness

Desc 2: F2, 12vDC Pow Harness - 40"

   Qty: 1

  1. Connect the C-6204-40 12VDC Power Harness to the H10 connection on the machine control assembly.

    1. Secure the green wire beneath the ground screw.

  2. Connect the opposite end of the C-6204-40 Power Adapter Harness (3-pin molex) to the F2 reader.

 I-P0023

Part #: C-6207

Desc 1: F2/F3, Alliance ACA Power

Desc 2:

   Qty: 1

  1. Connect the 2-pin connector from the C-6207 F2, ACA Power Harness to the 24v transformer behind the front control panel.
  2. The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
 I-S0031

Part #: C-6253

Desc 1: Coin Sense Harness

Desc 2: 28"

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6253 Coin Sense Harness to the harness connected to the Coin Slide Switch.

Connect Machine Interface Harness

 I-T0049

Part #: C-5300-NC

Desc 1: Machine Start Harness

Desc 2: Aliiance - Normally Closed

   Qty: 1

  1. Connect the C-5300-NC Machine Start Harness to the harness previously connected to the coin drop.
 I-T0040

Part #: C-5256

Desc 1: Machine Start Harns (pulse)

Desc 2: 20" - Male taps, Rq. Female

   Qty: 1

  1. Connect the C-5256 Machine Start Harness to the harness previously connected to the Coin Slide Switch.
 I-T0003

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: Alliance ACA

   Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connection on the Machine Control Assembly.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole.
  2. (Pulse Machine Interface Harnesses Only) Connect the free end of the C-5300-NC or C-5256 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. (Serial Communication / Serial Pulse Only) Connect the free end of the C-5240 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
  4. (Coin and Card Installations Only) Connect the free end of the C-6250 or C-6253 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  5. Connect the free end of the C-5500, C-6207, or C-6204-40 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.

Machine Configuration

ACA Controls

  1. Locate the dip switch on the back of the machine's control board.

  2. Set dip switch 3 to the ON position. 

  3. Leave all other dip switches as is.

Titanium Controls

  1. Enter Manual Mode by opening the service door and closing the coin vault switch. Then press the following two buttons based on the control:

    Quantum Gold Pro (T4)

    Galaxy 600 Pro (T2)

    MDC II (T1)

    High Temp & Med TempHigh Temp & Med Temp

    High Temp & Med Temp

  2. rAPid will be displayed on the control. Select the Prog option and then configure the following settings:

    1. Serial Payment Configuration (SErPAY): Card

    2. Card Enable (CArdEn): On

  3. Exit Manual Mode.

CCI Software Configuration

Machine ControlPulseSerial
Coin Slide Hybrid (Pulse)SingleVend (Relay) / -80ms*NOT SUPPORTED*
MDC II (A1)SingleVend (MLV+) / 80msAlliance ACA H7S Small Dryer A1 - MDC II
Quantum+ (A4)SingleVend (MLV+) / 80msAlliance ACA H7S Small Dryer A4 - Quantum+
Titanium (T1)SingleVend (MLV+) / 80msAlliance Titanium Small Dryer T1
Titanium (T4)SingleVend (MLV+) / 80msAlliance Titanium Small Dryer T4

  • No labels