Overview
Equipment Details
Type: Tumble Dryer (Stack)
Manufacturer: ADC
Make: ADC
Model Length: Not Set
Associated Models
AD30X2R
AD45X2R
ADG30X2R
ADG45X2R
Installation
Install Mounting Hardware
I-M0010
Part #: C-5801
Desc 1: F1 Reader Mounting Kit
Desc 2: Front
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-P0007
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5336 Power Adapter Harness to the power distribution panel inside the machine.
120vac: Connect the blue wire to L1 and the brown wire to N.
240vac: Connect the blue wire to L1 and brown wire to L2.
Secure the green wire beneath the ground screw.
Connect the opposite end of the C-5336 Power Adapter Harness to the C-5602R1 Power Converter.
Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602R1 Power Converter. The remaining cable end connects to the FasCard reader.
I-M0104
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0161
Part #: C-0926
Desc 1: Drop Cover
Desc 2: American 330
Qty: 1
Part #: C-1044N
Desc 1: Nut
Desc 2: M3 - Kep
Qty: 4
Part #: C-6602-V2
Desc 1: F2, Large Vault Mount
Desc 2: Modified version
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Part #: C-6601
Desc 1: Spacer
Desc 2: F2 Dexter Vault Filler Plate
Qty: 1
Part #: C-5751
Desc 1: Screw
Desc 2: 8-32 x 2-1/2" - Flat
Qty: 2
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Feed the harness ends through the coin vault opening and then through the circular opening in the C-6602 Vault Mount Bracket.
Spread the C-6602 Vault Mount Bracket wings outward and then insert the C-6602 Vault Mount Bracket into the coin vault.
Feed the harness ends through the C-5414 F2 Mounting Bracket and C-6601 Spacer Plate.
Secure the C-5414 F2 Mounting Bracket and C-6601 Spacer Plate to the C-6939 Vault Mount Bracket with the C-0144 Screws.
Install the C-5710 Rubber Grommet into the circular opening of the C-5414 F2 Mounting Bracket and C-6601 Spacer Plate.
Remove any existing coin drop.
Mount the C-0926 Drop Cover and secure in place with C-1044N Nuts.
Connect Power
I-P0007
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 2
Part #: C-5336
Desc 1: Power Adapter Harness
Desc 2: Dexter Stack
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
- Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
- Connect the C-5336 Power Adapter Harness to the installed spade taps- Blue to Black and Brown to Red. Secure the green ground terminal under the bolt on top of the washer drum.
- Connect the opposite end of the C-5336 Power Adapter Harness to the C-5602 Power Converter.
- Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0012
Part #: C-5343
Desc 1: Coin Sense Harness (SA)
Desc 2: ADC Phase 5
Qty: 1
- Disconnect the Coin Drop from the Machine Control Assembly.
- Connect the C-5343 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0022
Part #: C-5368
Desc 1: Coin Sense Harness
Desc 2: ADC Phase 7
Qty: 1
- Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5368 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0038
Part #: C-6343
Desc 1: Coin Sense Harness (SA)
Desc 2: ADC Phase 5
Qty: 1
- Disconnect the Coin Drop from the Machine Control Assembly.
- Connect the C-6343 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0049
Part #: C-6368
Desc 1: Coin Sense Harness (SA)
Desc 2: ADC Phase 7
Qty: 1
- Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6368 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
I-T0056
Part #: C-5344
Desc 1: Machine Start Harness
Desc 2: ADC Phase 5
Qty: 1
- Connect the C-5344 Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.
I-T0057
Part #: C-5345
Desc 1: Machine Start Harness
Desc 2: ADC Phase 7
Qty: 1
- Connect the C-5345 Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.
Connect and Mount Reader
- Feed remaining harness ends through the mounting hole as described in the F2/F3: FasCard Reader Mounting Guide.
- Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Harness to port 1.
- Secure the FasCard reader to base as described in the FasCard Mounting Guide.
Machine Configuration
None Required
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Phase 5 | SingleVend (Relay) / 60ms | *NOT SUPPORTED* |
Phase 7 | SingleVend (Relay) / 60ms | *NOT SUPPORTED* |