You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 5
Next »
Overview
Equipment Details
Type: Small Dryer (Single)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15
Associated Models
HDCBYRGS113CW01
HDEBCAGS173TW01
HDEBCRGS173TW01
HDEBCRGS175TW01
HDEBCRGS176TW01
HDEBYAGS173CW01
HDEBYAGS173TW01
HDEBYRGS116TW01
HDEBYRGS173TW01
HDESXRGS173TW01
HDGBCAGF116TW01
HDGBCAGS113TW01
HDGBCAGS116TW01
HDGBCASG116TW01
HDGBCRGF113TW01
HDGBCRGS113TW01
HDGBCRGS116EW01
HDGBCRGS116GW01
HDGBCRGS116TW01
HDGBYAGS113CW01
HDGBYAGS113TW01
HDGBYASP116TW01
HDGBYRGS1130T01
HDGBYRGS113TW01
HDGBYRGS116TW01
HDGSXRGS113TW01
HDSBYRGS116TW01
KDEBXRGS176TW01
KDESXAGS173YW01
KDESXRGS173TW01
KDGBXRGS115TW01
KDGBXRGS116TW01
KDNBXRGS173PW01
SDENCAGS1732W01
SDENCAGS173TW01
SDENCAGS176TW01
SDENCRGS173TW01
SDENCRGS173TW02
SDENCRGS176TW01
SDENXRGS173TW01
SDENYAGF173TW01
SDENYAGS103TW01
SDENYAGS116TW01
SDENYAGS153TW01
SDENYAGS1732W01
SDENYAGS173TW01
SDENYAGS176FW01
SDENYAGS176TW01
SDENYRGS173TW01
SDENYRGS176TW01
SDESXRGS173TW01
SDGNCAGS113TW01
SDGNCAGS116TW01
SDGNCAGS173PW01
SDGNCRGS113TW01
SDGNCRGS113TW02
SDGNCRGS116TW01
SDGNXRGS113TW02
SDGNXRGS116TW01
SDGNYAGS113TW01
SDGNYAGS116TW01
SDGNYRGF116TW01
SDGNYRGS113TW01
SDGNYRGS116TW01
SDGSXR2G113TW01
SDGSXRGF113EW01
SDGSXRGS113TW01
SDGSXRGS113TW02
SDGSXRSP115TW02
Installation
Install Mounting Hardware
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0136
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place C-5763 TWL Bracket in the intended mounting location. Using the bracket, mark the location of all four mounting holes.
Drill a hole at each marked location using a 3/16" drill bit.
Attach C-5414 Mounting Bracket to the front of C-5763 using two C-5420 screws.
Mount the C-5763 TLW Bracket using four C-5420 Screws and fasten from the inside of the panel.
I-M0142
Part #: C-5800
Desc 1: F1 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0078
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-1059
Desc 1: Nut
Desc 2: 10-32 - Kep
Qty: 2
Part #: C-1070-W
Desc 1: Washer - Build: XCH
Desc 2: 1/4" x 1" O.D.
Qty: 2
Part #: C-5027
Desc 1: Label
Desc 2: Credit Card Logo
Qty: 1
Part #: C-5765-W
Desc 1: Mounting Bracket
Desc 2: 10 Degree - White Finish
Qty: 1
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Remove existing coin box and coin drop.
Remove connections to coin vault service switch and bridge connections using C-5365 Bypass Harness.
Install C-5765-W Metercase Bracket over the front of the metercase and secure using the C-1059 Kep Nut, and C-1070-W Washer.
I-M0079
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-1059
Desc 1: Nut
Desc 2: 10-32 - Kep
Qty: 2
Part #: C-5027
Desc 1: Label
Desc 2: Credit Card Logo
Qty: 1
Part #: C-5760-A
Desc 1: Alliance Adapter Bracket
Desc 2: Mounts C-5760 to MeterCase
Qty: 1
Part #: C-5762
Desc 1: Metercase Bracket - High Cap
Desc 2: Coin Slide Ready Machine
Qty: 1
Part #: C-1070-W
Desc 1: Washer - Build: XCH
Desc 2: 1/4" x 1" O.D.
Qty: 2
Remove existing coin box and coin drop.
Remove connections to coin vault service switch and bridge connections using C-5365 Bypass Harness.
Install C-5762 Metercase Bracket over the front of the metercase and secure using the C-1059 Kep Nut, and C-1070-W Washer.
I-M0135
Part #: C-5801
Desc 1: F1 Reader Mounting Kit
Desc 2: Front
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0202
Part #: C-6762
Desc 1: Metercase Bracket
Desc 2: Coin Slide Ready Machine
Qty: 1
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-0301
Desc 1: Topload Mounting Bolt
Desc 2:
Qty: 1
Remove existing coin box and coin slide.
Attach C-5414 Standard Bracket to the C-6762 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.
Insert C-6762 Metercase Bracket into the metercase and secure using C-0301 Topload Mounting Bolt.
I-M0123
Part #: C-1059
Desc 1: Nut
Desc 2: 10-32 - Kep
Qty: 2
Part #: C-1070-W
Desc 1: Washer - Build: XCH
Desc 2: 1/4" x 1" O.D.
Qty: 2
Part #: C-5760-A
Desc 1: Alliance Adapter Bracket
Desc 2: Mounts C-5760 to MeterCase
Qty: 1
Part #: C-6762
Desc 1: Metercase Bracket
Desc 2: Coin Slide Ready Machine
Qty: 1
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Remove the coin drop and coin box.
Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.
Secure C-5414 F2 Mounting Bracket to the C-6903 Mounting Bracket using the (2) C-5420 10-32 x 1/4 Pan Screws.
Attach the C-5760-A Adapter Bracket to the C-6762 Mounting Bracket to the captured nut on the inside of the C-6762 Mounting Bracket.
Run all reader harnesses through the metercase and out the opening where the coin drop normally mounts.
Run all reader harnesses through the circular opening on the C-6762 Mounting Bracket.
Install the C-6762 Mounting Bracket into the front opening of the metercase so the two threaded posts of the C-5760-A Adapter Bracket line up with the openings for the coin slots. Secure in place using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.
I-M0119
Part #: C-1059
Desc 1: Nut
Desc 2: 10-32 - Kep
Qty: 2
Part #: C-1070-W
Desc 1: Washer - Build: XCH
Desc 2: 1/4" x 1" O.D.
Qty: 2
Part #: C-6765-W-R1
Desc 1: F2 Mounting Bracket
Desc 2: 10 Degree - White Finish
Qty: 1
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Remove existing coin box and coin drop.
Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
Attach the C-5414 F2 Mounting Bracket to the C-6765-W-R1 Metercase Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.
Run any card reader harnesses through the coin slot openings and the circular hole in the C-6765-W-R1 Metercase Bracket.
Install the C-6765-W-R1 Metercase Bracket so that the two threaded posts insert into the coin drop slots. Then secure it to the machine using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.
I-M0205
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-5027
Desc 1: Label
Desc 2: Credit Card Logo
Qty: 1
Part #: C-5762
Desc 1: Metercase Bracket - High Cap
Desc 2: Coin Slide Ready Machine
Qty: 1
Part #: C-0301
Desc 1: Topload Mounting Bolt
Desc 2:
Qty: 1
Remove existing coin box and coin slide.
Install C-5762 Metercase Bracket over the front of the metercase and secure using the C-0301 Mounting Bolt.
Connect Power
I-P0003
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Use the C-5101 Spade Taps on the incoming power.
Tap the L1 wire.
Tap the N wire.
Tap the Ground wire.
Take the C-5210 Power Adapter Harness and connect the red tab connectors to the following wires:
Connect the blue wire to the L1 wire.
Connect the brown wire to the N wire.
Connect the green/yellow wire to the Ground wire.
Connect the 3-pin connector from the C-5210 Power Adapter Harness to the matching connection on the C-5602R1 Power Converter.
Connect the 4-pin connector from the C-5602R1 Power Converter to the matching connection on the C-5500 Power Extension Harness.
I-P0002
Part #: C-6204-40
Desc 1: Power Adapter Harness
Desc 2: F2, 12vDC Pow Harness - 40"
Qty: 1
Connect the C-6204-40 12VDC Power Harness to the H10 connection on the machine control assembly.
Secure the green wire beneath the ground screw.
Connect the opposite end of the C-6204-40 Power Adapter Harness (3-pin molex) to the F2 reader.
I-P0023
Part #: C-6207
Desc 1: F2/F3, Alliance ACA Power
Desc 2:
Qty: 1
Connect the 2-pin connector from the C-6207 F2, ACA Power Harness to the 24v transformer behind the front control panel.
The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.
Connect Coin Sense Harness
I-S0001
Part #: C-5250
Desc 1: Coin Sense Harness
Desc 2:
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5250 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0004
Part #: C-5253
Desc 1: Coin Sense Harness
Desc 2: 28"
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5253 Coin Sense Harness to the micro switch on the coin slide.
I-S0027
Part #: C-6250
Desc 1: Coin Sense Harness
Desc 2: F2
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0031
Part #: C-6253
Desc 1: Coin Sense Harness
Desc 2: 28"
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6253 Coin Sense Harness to the harness connected to the Coin Slide Switch.
Connect Machine Interface Harness
I-T0049
Part #: C-5300-NC
Desc 1: Machine Start Harness
Desc 2: Aliiance - Normally Closed
Qty: 1
Connect the C-5300-NC Machine Start Harness to the harness previously connected to the coin drop.
I-T0040
Part #: C-5256
Desc 1: Machine Start Harns (pulse)
Desc 2: 20" - Male taps, Rq. Female
Qty: 1
Connect the C-5256 Machine Start Harness to the harness previously connected to the Coin Slide Switch.
I-T0003
Part #: C-5240
Desc 1: Machine Start Harness
Desc 2: Alliance ACA
Qty: 1
Connect the C-5240 Machine Start Harness to the H3 connection on the Machine Control Assembly.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
ACA Controls
Locate the dip switch on the back of the machine's control board.
Set dip switch 3 to the ON position.
Leave all other dip switches as is.
Titanium Controls
Enter Manual Mode by opening the service door and closing the coin vault switch. Then press the following two buttons based on the control:
Quantum Gold Pro (T4) | Galaxy 600 Pro (T2) | MDC II (T1) |
---|
High Temp & Med Temp | High Temp & Med Temp | High Temp & Med Temp |
rAPid will be displayed on the control. Select the Prog option and then configure the following settings:
Serial Payment Configuration (SErPAY): Card
Card Enable (CArdEn): On
Exit Manual Mode.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Coin Slide Hybrid (Pulse) | SingleVend (Relay) / -80ms | *NOT SUPPORTED* |
MDC II (A1) | SingleVend (MLV+) / 80ms | Alliance ACA H7S Small Dryer A1 - MDC II |
Quantum+ (A4) | SingleVend (MLV+) / 80ms | Alliance ACA H7S Small Dryer A4 - Quantum+ |
Titanium (T1) | SingleVend (MLV+) / 80ms | Alliance Titanium Small Dryer T1 |
Titanium (T4) | SingleVend (MLV+) / 80ms | Alliance Titanium Small Dryer T4 |