Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Tumble Dryer (Single)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 16 to 18

Alliance ACA Tumbler Dryer (Single)

Associated Models


HT030NBCANXG3W0000
HT030NBCARXG5W0000
HT030NBY0RBG5W0000
HT030NNCARBG6W0000
HT030NNY0RBG6W0000
HT030NNY0RXS6NC000
HT030NNYDRBG6W0000
HT030NWY0RXS5NC000
HT030NWY0RXS6NC000
HT030NWYORXS5NC000
HT035EFN0RLG6W0000
HT050NWCANBG3NC0A0
HT055NBCANBG3W0000
HT055NBCARX55NC000
HT055NBDARXF5NB000
HT055NNCARBG6W0000
HT055NNCARXS6NC000
HT055NWCARBS5NC0A0
HT055NWY0RBS6NC0A0
HT075LNCARBS6NC000
HT075LNY0RXS6NC000
HT075NBCANBG3N0000
HT075NBCANBG3W0000
HT075NBCANXG3N0000
HT075NBCARBG5W0000
HT075NBCARXS5NC000
HT075NBY0NBG3W0000
HT075NBY0RXS5NC000
HT075NBYGRXS5NC000
HT075NNC0NBG3NC000
HT075NNCANBG3NC000
HT075NNCANXG3N0000
HT075NNCANXG3NC0C0
HT075NNCANXG3W0000
HT075NNCARBG6W0000
HT075NNCARBS6NC0A0
HT075NNCARXG6W0000
HT075NNCARXS6NC000
HT075NNCARXS6NC0A0
HT075NNX0RXS6NC000
HT075NNY0RBS6NC000
HT075NNY0RX56N00
HT075NNY0RX56NC000
HT075NNY0RXG6W0000
HT075NNY0RXS6NC000
HT075NWC0RXS6NC000
HT075NWCANBG3N0000
HT075NWCANBG3N00C0
HT075NWCANBG3NC0A0
HT075NWCANXG3N00A0
HT075NWCANXG3NC000
HT075NWCANXG3NC0C0
HT075NWCANXG5N00A0
HT075NWCANXG5NC0
HT075NWCANXG5NC0A0
HT075NWCARB85NC000
HT075NWCARBS5NC000
HT075NWCARBS5NC0A0
HT075NWCARBS5NCA00
HT075NWCARBS6NC000
HT075NWCARXS5NC0A0
HT075NWCARXS6NC000
HT075NWL0NXS3NC0A0
HT075NWP0RXS5NC000
HT075NWP0RXS6NC000
HT075NWY0NBG3N0000
HT075NWY0NBG3N00A0
HT075NWY0NBG3N00C0
HT075NWY0NBG3NC0A0
HT075NWY0NBG3NC0C0
HT075NWY0NBS3N0000
HT075NWY0NXG3N0000
HT075NWY0NXG3N00A0
HT075NWY0NXG3NC0A0
HT075NWY0NXG3W0000
HT075NWY0RBG3NC0A0
HT075NWY0RBG3NC0C0
HT075NWY0RBS6NC000
HT075NWY0RBS6NC0A0
HT075NWY0RXS5NC000
HT075NWY0RXS5NC0A0
HT075NWY0RXS5NC0C0
HT075NWY0RXS6NC000
HT075NWYORXS5NC000
HT075NWYORXS5NC0C0
KT030NBCANXS3WA000
KT030NNCARXH6W00
KT030NNY0RBH6N0000
KT055NBCARXS3W00
KT055NNCARXH6N00
KT055NNCARXS3W00
KT055NNCARXS3W0000
KT075NBCARXH3N0000
KT075NBCARXH3W00
KT075NBCARXS3W00
KT075NBY0NBH3N00
KT075NBY0NBH3N0000
KT075NBY0NXH3N0000
KT075NFN0RXH6N00
KT075NNCABXH3W00
KT075NNCANBH3W00
KT075NNCANBH3W0000
KT075NNCANXH3N00
KT075NNCARBH3N00
KT075NNCARBH3W00
KT075NNCARBH6N0000
KT075NNCARXH3N00
KT075NNCARXH3N0000
KT075NNCARXH3W00
KT075NNCARXH6N00
KT075NNCARXH6N0000
KT075NNCARXH6W00
KT075NNCARXS3W0000
KT075NNY0RB86N00
KT075NNY0RBH3N00
KT075NNY0RBH6N00
KT075NNY0RBH6N0000
KT075NNY0RDH6N0000
KT075NNY0RNH3N00
KT075NNY0RNH3N0000
KT075NNY0RXH3N00
KT075NNY0RXH3N0000
KT075NNY0RXH6N00
KT075NNY0RXH6N0000
KT075NNYCRXH3N0000
KT075NNYORBH3N0000
KT075NNYORXH3N00
KT075NNYORXH6N00
KT075NNYORXH6W00
PT075NNCANBG3N0000
ST030LNY0RBG6W0000
ST030NBDANBG3WA000
ST030NNCANBG3N0000
ST030NNCARBG6W0000
ST030NNY0RBS6NC000
ST030NWDANBG3WA000
ST035NNY0RXG5W0000
ST050NBCARBG5W0000
ST050NNCANBG3W0000
ST055EWY0NDG3W0000
ST055NNCARBS6NC000
ST055NNCARXS5NC000
ST055NNCARXS6NC000
ST055NWDANBG3WA000
ST075LNCARBS5NC000
ST075NBCANBG3W0000
ST075NBCARBS6NC000
ST075NBY0RBG5W0000
ST075NBYANBS4NC000
ST075NNCANBG3N0000
ST075NNCANXG3N0000
ST075NNCARBF6NC000
ST075NNCARBG5W0000
ST075NNCARBG6W0000
ST075NNCARBG6W00C0
ST075NNCARBS5N0000
ST075NNCARBS6NC000
ST075NNCARCS6NC0
ST075NNCARXG5W0000
ST075NNCARXG6W0000
ST075NNCARXS6NC000
ST075NNDANBG3N0000
ST075NNDANBS3N0000
ST075NNX0RBS6NC000
ST075NNY0NXG3N0000
ST075NNY0RBS6NC000
ST075NNY0RXG6W0000
ST075NNY0RXS6NC000
ST075NNYORBS6NC000
ST075NWCANBG3N0000
ST075NWCANBG3W0000
ST075NWCANXG3N0000
ST075NWCARBG3W0000
ST075NWCARBS6NC000
ST075NWCARXG3N0000
ST075NWCARXS6NC000
ST075NWX0NBG3N0000
ST075NWY0RBS6NC000
ST075NWY0RXS6NC000

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2 FasCard Reader Mounting Guide for further instructions.

 I-M0118

Part #: C-0144

Desc 1: Screw

Desc 2: 8-32 x 2" - Flat

   Qty: 2

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-5710

Desc 1: Rubber Grommet

Desc 2: 3/4"

   Qty: 1

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

Part #: C-6936

Desc 1: F2, Sm Vault Mount Bracket

Desc 2:

   Qty: 1

Part #: C-5033

Desc 1: Label

Desc 2: 4-5/8" x 3-1/2"

   Qty: 1

  1. Remove existing coin box.

  2. Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.
  3. Bend the side tabs of the C-6936 Vault Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.

  4. Secure the C-5414 Standard Mounting Bracket to the C-6936 Vault Bracket with C-0144 Screws.
 I-M0127

Part #: C-1060

Desc 1: Screw - Build: TK

Desc 2: 8-32 x 3/8" - Zinc

   Qty: 2

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

Part #: C-6970R1

Desc 1: F2, Bracket (revised)

Desc 2: Alliance Card Ready

   Qty: 1

  1. Install the C-6970 Alliance Mounting Bracket into the opening on the control panel for mounting card readers and coin drops.
  2. Attach the C-5414 F2 Mounting Bracket to the C-6970 Alliance Mounting Bracket and secure using the C-1060 Screws.
  3. Refer to F2 FasCard Reader Mounting Guide for further instructions.

Connect Power

 I-P0002

Part #: C-6204-40

Desc 1: Power Adapter Harness

Desc 2: F2, 12vDC Pow Harness - 40"

   Qty: 1

  1. Connect the C-6204-40 Power Adapter Harness (12VDC power) to the H10 connection on the Machine Control Assembly.

    1. Secure the green wire beneath the ground screw.

Connect Coin Sense Harness

 I-S0027

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: F2

   Qty: 1

  1. Disconnect the coin drop from the machine control assembly.
  2. Connect the C-6250 Coin Sense Harness to the harness connected to the coin drop.
 I-S0055

Part #: C-6250

Desc 1: Coin Sense Harness

Desc 2: can use C-6250-144

   Qty: 2

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect a C-6250 Coin Sense Harness to the harness connected to the Coin 1 Drop.
  3. Connect a C-6250 Coin Sense Harness to the harness connected to the Coin 2 Drop.

Connect Machine Interface Harness

 I-T0003

Part #: C-5240

Desc 1: Machine Start Harness

Desc 2: Alliance ACA

   Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.
  1. Feed remaining harness ends through mounting hole as described in F2 FasCard Reader Mounting Guide.
  2. Connect the free end of the C-5240 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
  3. Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin 1 Sense Harness Connection Port) as shown in the image above.
    1. If using a dual coin drop, connect the second C-6250 Coin Sense Harness to port 4 (Coin 2 Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-6204-40 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.
  5. Connect FasCard reader to base as described in the F2 FasCard Reader Mounting Guide.

Machine Configuration

ACA machines using a serial configuration require dip switch 3 on the Machine Control Board to be set to the 'ON' position. Leave all other dip switches as is.

CCI Software Configuration

Machine ControlPulseSerial
Dual Digital Timer (OPL)*NOT SUPPORTED**NOT SUPPORTED*
EVO7S*NOT SUPPORTED**NOT SUPPORTED*
Galaxy (OPL)*NOT SUPPORTED**NOT SUPPORTED*
Galaxy 600 (A2)SingleVend (MLV+) / 80msAlliance ACA H7S Tumbler Dryer A2 - Galaxy 600
MDC II (A1)SingleVend (MLV+) / 80msAlliance ACA H7S Tumbler Dryer A1 - MDC II
Micro (OPL)*NOT SUPPORTED**NOT SUPPORTED*
M-Series (OPL)*NOT SUPPORTED**NOT SUPPORTED*
OPTimum (OPL)*NOT SUPPORTED**NOT SUPPORTED*
Quantum Gold (OPL)*NOT SUPPORTED**NOT SUPPORTED*
Quantum+ (A4)SingleVend (MLV+) / 80msAlliance ACA H7S Tumbler Dryer A4 - Quantum+
UniLinc (OPL)*NOT SUPPORTED**NOT SUPPORTED*
XQ*NOT SUPPORTED**NOT SUPPORTED*