You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 9
Next »
Overview
Equipment Details
Type: Small Dryer (Stack)
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15
6th character is panel type:
A - 10deg Front Control Panel
F - Flat Front Control Panel
Associated Models
HSEBCAGS116TW01
HSEBCAGW173TW01
HSEBYAGS173TW01
HSEBYAGW173TW01
HSEBYAGW176TW01
HSGBCAGS116TW01
HSGBCAGW113TW01
HSGBCAGW116TW01
HSGBYAGS113TW01
HSGBYAGS116TW01
HSGBYAGW113TW01
HSGBYAGW116TW01
KSEBXAGS176TW01
KSGBXAGS115TW01
KSGBXAGS176TW01
KSGSXAGS113TW01
SSENCAGS153TW01
SSENCAGS173TW01
SSENCAGW173TW01
SSENCFGS173TW01
SSENXAGW173TW01
SSENYAGS173TW01
SSENYAGS175TW01
SSENYAGS176TW01
SSENYAGW176TW01
SSENYFGS176TW01
SSENYFGW175TW01
SSENYFGW176TW01
SSGNCAGS113TW01
SSGNCAGS116TW01
SSGNCAGW113TW01
SSGNCFGS113TW01
SSGNCFGS116TW01
SSGNXAGS113TW01
SSGNXAGW113TW01
SSGNYAGS113TW01
SSGNYAGS116TW01
SSGNYAGW116TW01
SSGNYFGS113TW01
SSGNYFGS116TW01
SSGSXAGS113TW01
Installation
Install Mounting Hardware
I-M0003
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0010
Part #: C-5801
Desc 1: F1 Reader Mounting Kit
Desc 2: Front
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0078
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-1059
Desc 1: Nut
Desc 2: 10-32 - Kep
Qty: 2
Part #: C-1070-W
Desc 1: Washer - Build: XCH
Desc 2: 1/4" x 1" O.D.
Qty: 2
Part #: C-5027
Desc 1: Label
Desc 2: Credit Card Logo
Qty: 1
Part #: C-5765-W
Desc 1: Mounting Bracket
Desc 2: 10 Degree - White Finish
Qty: 1
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Remove existing coin box and coin drop/slide.
Remove vault service switch connections from the switch and bridge using the C-5365 Bypass Harness.
Install C-5765-W Vault Bracket over the metercase opening. Secure in place using C-1059 Kep Nuts and C-1070-W Washers.
If installing on a coin slide equipped model the two holes next to the coin slide bolt will need to be enlarged about a 1/4" to allow the mounting studs to pass through the metercase.
Apply C-5027 Label on or near the reader if required for location.
I-M0119
Part #: C-1059
Desc 1: Nut
Desc 2: 10-32 - Kep
Qty: 2
Part #: C-1070-W
Desc 1: Washer - Build: XCH
Desc 2: 1/4" x 1" O.D.
Qty: 2
Part #: C-6765-W-R1
Desc 1: F2 Mounting Bracket
Desc 2: 10 Degree - White Finish
Qty: 1
Part #: C-5365
Desc 1: Bypass Harness
Desc 2: Alliance Coin Vault Bypass
Qty: 1
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Remove existing coin box and coin drop.
Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
Attach the C-5414 F2 Mounting Bracket to the C-6765-W-R1 Metercase Bracket using C-5702 Chase Nipple and C-5703 Lock Nut.
Run any card reader harnesses through the coin slot openings and the circular hole in the C-6765-W-R1 Metercase Bracket.
Install the C-6765-W-R1 Metercase Bracket so that the two threaded posts insert into the coin drop slots. Then secure it to the machine using the C-1059 Kep Nuts and C-1070-W Washers.
I-M0135
Part #: C-5801
Desc 1: F1 Reader Mounting Kit
Desc 2: Front
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
I-M0136
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
Connect Power
I-P0002
Part #: C-6204-40
Desc 1: Power Adapter Harness
Desc 2: F2, 12vDC Pow Harness - 40"
Qty: 1
Connect the C-6204-40 12VDC Power Harness to the H10 Connection on the Machine Control Assembly.
Connect the green wire to a chassis ground.
The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.
I-P0023
Part #: C-6207
Desc 1: F2/F3, Alliance ACA Power
Desc 2:
Qty: 1
Connect the 2-pin connector from the C-6207 F2, ACA Power Harness to the 24v transformer behind the front control panel.
The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.
I-P0003
Part #: C-5101
Desc 1: Spade Taps
Desc 2: 18-14 AWG
Qty: 3
Part #: C-5210
Desc 1: Power Adapter Harness
Desc 2: CGI
Qty: 1
Part #: C-5500
Desc 1: Power Extension Harness
Desc 2: 25.5"
Qty: 1
Part #: C-5602R1
Desc 1: Power Converter
Desc 2: SMT-012-018VW
Qty: 1
Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
I-S0027
Part #: C-6250
Desc 1: Coin Sense Harness
Desc 2: F2
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0031
Part #: C-6253
Desc 1: Coin Sense Harness
Desc 2: 28"
Qty: 1
Locate the micro switch on the coin slide assembly for the upper pocket.
Disconnect the harness connected to the microswitch and connect C-6253 Coin Sense Harness to the spade tabs on the micro switch.
Connect Machine Interface Harness
I-T0049
Part #: C-5300-NC
Desc 1: Machine Start Harness
Desc 2: Aliiance - Normally Closed
Qty: 1
Connect the C-5300-NC Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.
I-T0003
Part #: C-5240
Desc 1: Machine Start Harness
Desc 2: Alliance ACA
Qty: 1
Connect the C-5240 Machine Start Harness to the the H3 connection on the Machine Control Assembly or Communication board.
I-T0040
Part #: C-5256
Desc 1: Machine Start Harns (pulse)
Desc 2: 20" - Male taps, Rq. Female
Qty: 1
Connect the C-5256 Machine Start Harness to the the harness previously connected to the coin slide microswitch spade tabs.
I-X0008
Part #: C-5240
Desc 1: Machine Start Harness
Desc 2: can use C-5240-144
Qty: 1
Part #: C-6250
Desc 1: Coin Sense Harness
Desc 2: can use C-6250-144
Qty: 1
Part #: C-6401
Desc 1: Stack Add On Board - MLV
Desc 2: Serial / MultiVend
Qty: 1
Run C-5240 Machine Start Harness and C-6250 Coin Sense Harness to the second Machine Control Assembly.
Connect C-5240 Machine Start Harness to the H3 connection and the C-6250 Coin Sense Harness to the Coin 1 connection on the second Machine Control Assembly.
Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.
Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.
Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.
Connect the Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the F2 reader.
Connect the Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the F2 reader.
I-X0019
Part #: C-5240
Desc 1: Machine Start Harness
Desc 2: can use C-5240-144
Qty: 1
Part #: C-6401
Desc 1: Stack Add On Board - MLV
Desc 2: Serial / MultiVend
Qty: 1
Connect the C-5240 Machine Start Harness to the the H3 connection on the Machine Control Assembly or Communication board on the lower pocket control.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
ACA Controls
Locate the dip switch on the back of the machine's control board.
Set dip switch 3 to the ON position.
Leave all other dip switches as is.
Titanium Controls
Enter Manual Mode by opening the service door and closing the coin vault switch. Then press the following two buttons based on the control:
Quantum Gold Pro (T4) | Galaxy 600 Pro (T2) | MDC II (T1) |
---|
High Temp & Med Temp | High Temp & Med Temp | High Temp & Med Temp |
rAPid will be displayed on the control. Select the Prog option and then configure the following settings:
Serial Payment Configuration (SErPAY): Card
Card Enable (CArdEn): On
Exit Manual Mode.
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Coin Slide Hybrid (Pulse) | SingleVend (Relay) / 80ms | *NOT SUPPORTED* |
MDC II (A1) | SingleVend (MLV+) / 80ms | Alliance ACA H7S Small Dryer A1 - MDC II |
Quantum+ (A4) | SingleVend (MLV+) / 80ms | Alliance ACA H7S Small Dryer A4 - Quantum+ |
Titanium (T1) | SingleVend (MLV+) / 80ms | Alliance Titanium Small Dryer T1 |
Titanium (T4) | SingleVend (MLV+) / 80ms | Alliance Titanium Small Dryer T4 |