Warning!
This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.
It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.
Overview
Equipment Details
Type: Front Load Washer
Manufacturer: Alliance
Make: [VARIES]
Model Length: 15
If equipped with electronic coin drop that uses existing H10 power connector, send I-P0007 power kit instead.
Associated Models
BFNBCASG113TN01
BFNBCASG113TW01
BFNBCASP113TW01
BFNBYAJP113TW01
BFNBYASP113TW01
HFGBYAGF113TW01
HFMBCASP113CW01
HFMBYASP113CW01
HFNBCAGS113TW01
HFNBCASG113TN01
HFNBCASG113TW01
HFNBCASG115TW01
HFNBCASP113TN01
HFNBCASP113TW01
HFNBCASP115TW01
HFNBCASP115TW02
HFNBCAST113TW01
HFNBCRSP115TW01
HFNBCRST115TW01
HFNBXASP113CW01
HFNBXASP115CW01
HFNBYAFP115CW01
HFNBYASP113CW01
HFNBYASP115CW01
HFNBYASP115TW01
HFNBYAST115CW01
HFNKCA8P116PW01
HFNKCA8P116TW01
HFNKCAF6116PW01
HFNKCAFG113TN01
HFNKCAFP116TW01
HFNKCAFT115TN01
HFNKCAPS116TW01
HFNKCASD115TN01
HFNKCASG113TN01
HFNKCASG113TN31
HFNKCASG113TN32
HFNKCASG113TW01
HFNKCASG115TN01
HFNKCASG115TN32
HFNKCASG115TW01
HFNKCASG116TN01
HFNKCASG116TW01
HFNKCASP113TN31
HFNKCASP113TN32
HFNKCASP115TN01
HFNKCASP115TN31
HFNKCASP115TW01
HFNKCASP116TN01
HFNKCASP116TW01
HFNKCAST116CW01
HFNKCASZ113TN01
HFNKDA8P116PW01
HFNKEAFG115TN01
HFNKXASG113CN01
HFNKXASG115CN01
HFNKXASG115CN32
HFNKXASG115CW01
HFNKXASP115CN01
HFNKXASP115CN32
HFNKXASP115CW01
HFNKYASG113CN01
HFNKYASG113CW01
HFNKYASG113TW01
HFNKYASG115CN01
HFNKYASG115CN31
HFNKYASG116CN01
HFNKYASP115CN01
HFNKYASP115CW01
HFNKYASP115TW01
HFNKYASP116CN01
HFNNCASG116TW01
HFNNYASG116TW01
PFNJCASG115TG01
PFNJCASG115TN01
PFNJCASP115TG01
PFNJXASP114TG01
PFNJXASP115TG01
SFNBCASG113TW01
SFNBCASP113TW01
SFNBCRSP113TW01
SFNBXASP113TW01
SFNBYRSP113TW01
SFNKCA8G1157W01
SFNNCAFG113TW01
SFNNCAFG115TN01
SFNNCAGS113TN01
SFNNCAS4116TW01
SFNNCASG113TN01
SFNNCASG113TW01
SFNNCASG115TN01
SFNNCASG115TW01
SFNNCASG116TN01
SFNNCASG116TW01
SFNNCASP113TN01
SFNNCASP113TW01
SFNNCASP114TW01
SFNNCASP115PW01
SFNNCASP115TN01
SFNNCASP115TW01
SFNNCASP116EW01
SFNNCASP116PW01
SFNNCASP116TN01
SFNNCASP116TW01
SFNNCAST115TW01
SFNNCAZP115TW01
SFNNCRSG115TW02
SFNNCRSP115TW02
SFNNCRSP116TW01
SFNNXASG113TW01
SFNNXASG115TN01
SFNNXASG115TW01
SFNNXASP113TN01
SFNNXASP113TW01
SFNNXASP115TW01
SFNNXASP116TW01
SFNNXRSP115TW02
SFNNYA8P115TW01
SFNNYAGS116PW01
SFNNYAGS116TW01
SFNNYAJP115TW01
SFNNYASG113TN01
SFNNYASP113TW01
SFNNYASP115TW01
SFNNYASP116TW01
SFNNYASP225TW01
SFNNYAST115TW01
SFNNYAST116TW01
SFNNYATP115TW01
SFNNYRSP115TW01
SFNNYRSP116TW01
SFNWCASG113TN01
SFNWCASG1151N01
SFNWCASG115TN01
Recommended Tools and Supplies
Drill
1 1/8" Tungsten Carbide Tipped Hole Cutter
Cutting Oil
9/64" Drill Bit
Center Punch
Hammer
Fine Point Permanent Marker
Pliers
Tape Measure
Installation
Install Mounting Hardware
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
Feed remaining harness ends through the mounting hole.
Connect the free end of the C-5240 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
(Coin and Card Installations Only) Connect the free end of the Coin 1 C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
(Coin and Card Installations with Factory Dual Optical kits Only) Connect the free end of the Coin 2 C-6250 Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the C-6207 or C-6204-40 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.
Machine Configuration
Locate the dip switch on the back of the machine's control board. Set dip switch 3 to the ON position. Leave all other dip switches as is.ACA Controls
Enter Manual Mode by opening the service door and closing the coin vault switch. Then press the following two buttons based on the control: Quantum Gold Pro (T4) Galaxy 600 Pro (T2) MDC II (T1) Normal Hot & Perm Press Warm rAPid will be displayed on the control. Select the Prog option and then configure the following settings: Serial Payment Configuration (SErPAY): Card Card Enable (CArdEn): On Exit Manual Mode.Titanium Controls
Regular & Normal Hot & Blankets Cold
CCI Software Configuration
Machine Control | Pulse | Serial |
---|---|---|
Coin Slide Hybrid (Pulse) | SingleVend (Relay) / -80ms | *NOT SUPPORTED* |
Galaxy 600 (A2) | SingleVend (MLV+) / 80ms | Alliance ACA H7S Front Load Washer A2 - Galaxy 600 |
International (A3) | SingleVend (MLV+) / 80ms | Alliance ACA H7S Front Load Washer A3 - International |
MDC II (A1) | SingleVend (MLV+) / 80ms | Alliance ACA H7S Front Load Washer A1 - MDC II |
Quantum+ (A4) | SingleVend (MLV+) / 80ms | Alliance ACA H7S Front Load Washer A4 - Quantum+ |
Titanium (T1) | SingleVend (MLV+) / 80ms | Alliance Titanium Front Load Washer T1 |
Titanium (T2) | SingleVend (MLV+) / 80ms | Alliance Titanium Front Load Washer T2 |
Titanium (T4) | SingleVend (MLV+) / 80ms | Alliance Titanium Front Load Washer T4 |
Additional Resources
- How to Program Address on a FasCard Reader
- FasCard Admin Site - Equipment Setup
- FasCard Admin Site - Machine Setup
- FasCard Admin Site - Pricing & Features Schedule
- F1 Reader Mounting Guide
- FasCard F2/F3 Reader Installation Guide - Front Mount
- FasCard Installation Videos
- FasCard Kit Installations - Machine Configurations & Related Documents