Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer
Manufacturer: Laundrylux
Make: Wascomat
Model Length: 4

Customer must provide what starting/payment device is installed on machine.

Associated Models


W105
W125
W185

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0131

Part #: C-1059

Desc 1: Nut

Desc 2: 10-32 - Kep

   Qty: 2

Part #: C-6920R1

Desc 1: Mounting Bracket

Desc 2: 6" Straight w/ studs

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove existing coin box and coin drop.

  2. Attach the C-5414 F2 Mounting Bracket to the C-6920R1 Vault Mount Bracket using the C-5420 Screws.

  3. Install C-6920R1 Vault Mount Bracket into the coin vault. Secure in place with C-1059 Kep Nuts.

Connect Power

Connect Coin Sense Harness

 I-S0052

Part #: C-6389

Desc 1: Coin Sense Harness

Desc 2: Set-O-Matic

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6389 Coin Sense Harness to the harness connected to the Coin Drop.

 I-C0017

Part #: C-6380

Desc 1: Combination Harness (SA)

Desc 2: Keltner SR1-WIR 110-220v

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6380 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0027

Part #: C-0119R1F

Desc 1: Machine Start Harness

Desc 2: Pins 1&4 on End B - Rotary

   Qty: 1

  1. Connect the C-0119R1F Machine Start Harness to the X21 connection on the Machine Control Assembly.

 I-C0017

Part #: C-6380

Desc 1: Combination Harness (SA)

Desc 2: Keltner SR1-WIR 110-220v

   Qty: 1

  1. Connect the C-6380 Machine Start Harness to the X21 connection on the Machine Control Assembly.

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO

CCI Software Configuration

Machine ControlPulseSerial
*NO NAME*SingleVend (Relay) / 500ms*NOT SUPPORTED*
Keltner - PulseSingleVend (Relay) / 1000ms*NOT SUPPORTED*
Rotary Timer - PulseSingleVend (Relay) / 2000ms*NOT SUPPORTED*
Set-O-Matic - PulseSingleVend (Relay) / 100ms*NOT SUPPORTED*

  • No labels