Skip to end of metadata
Go to start of metadata
You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 6
Next »
Overview
Equipment Details
Type: Tumble Dryer (Stack)
Manufacturer: ADC
Make: ADC
Model Length: Not Set
Associated Models
AD30X2R
AD45X2R
ADG30X2R
ADG45X2R
Installation
Install Mounting Hardware
I-M0010
Part #: C-5801
Desc 1: F1 Reader Mounting Kit
Desc 2: Front
Qty: 1
Place the C-5700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to F1 Reader Mounting Guide for further instructions.
I-M0042
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Part #: C-1042
Desc 1: Nut
Desc 2: 8-32 - Kep
Qty: 2
Part #: C-1043
Desc 1: Screw
Desc 2: 8-32 x 1-3/4" - Flat
Qty: 2
Install reader into card reader opening and secure with C-1042 Nut and C-1043 Screw.
I-M0043
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
CCI Ready Machines will already have the proper mounting and will only need to be secured to the machine using the C-0141 Screws.
I-M0104
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard F2/F3 Reader Installation Guide - Front Mount for further instructions.
I-M0161
Part #: C-0926
Desc 1: Drop Cover
Desc 2: American 330
Qty: 1
Part #: C-1044N
Desc 1: Nut
Desc 2: M3 - Kep
Qty: 4
Part #: C-6602-V2
Desc 1: F2, Large Vault Mount
Desc 2: Modified version
Qty: 1
Part #: C-6801
Desc 1: F2/F3 Reader Mounting Kit
Desc 2: Universal
Qty: 1
Part #: C-6601
Desc 1: Spacer
Desc 2: F2 Dexter Vault Filler Plate
Qty: 1
Part #: C-5751
Desc 1: Screw
Desc 2: 8-32 x 2-1/2" - Flat
Qty: 2
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Feed the harness ends through the coin vault opening and then through the circular opening in the C-6602 Vault Mount Bracket.
Spread the C-6602 Vault Mount Bracket wings outward and then insert the C-6602 Vault Mount Bracket into the coin vault.
Feed the harness ends through the C-5414 F2 Mounting Bracket and C-6601 Spacer Plate.
Secure the C-5414 F2 Mounting Bracket and C-6601 Spacer Plate to the C-6939 Vault Mount Bracket with the C-0144 Screws.
Install the C-5710 Rubber Grommet into the circular opening of the C-5414 F2 Mounting Bracket and C-6601 Spacer Plate.
Remove any existing coin drop.
Mount the C-0926 Drop Cover and secure in place with C-1044N Nuts.
I-M0221
Part #: C-5710
Desc 1: Rubber Grommet
Desc 2: 3/4"
Qty: 1
Part #: C-6802
Desc 1: FLEX RF Reader Mounting Kit
Desc 2:
Qty: 1
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard F2/F3 Reader Installation Guide - Front Mount for further instructions.
Instructions do not exist for Kit I-M0263
Connect Coin Sense Harness
I-S0012
Part #: C-5343
Desc 1: Coin Sense Harness (SA)
Desc 2: ADC Phase 5
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5343 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0022
Part #: C-5368
Desc 1: Coin Sense Harness
Desc 2: ADC Phase 7
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-5368 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0038
Part #: C-6343
Desc 1: Coin Sense Harness (SA)
Desc 2: ADC Phase 5
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6343 Coin Sense Harness to the harness connected to the Coin Drop.
I-S0049
Part #: C-6368
Desc 1: Coin Sense Harness (SA)
Desc 2: ADC Phase 7
Qty: 1
Disconnect the Coin Drop from the Machine Control Assembly.
Connect the C-6368 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
I-T0057
Part #: C-5345
Desc 1: Machine Start Harness
Desc 2: ADC Phase 7
Qty: 1
Connect the C-5345 Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
Machine Configuration
None Required
CCI Software Configuration
Machine Control | Pulse | Serial |
---|
Phase 5 | SingleVend (Relay) / 60ms | *NOT SUPPORTED* |
Phase 7 | SingleVend (Relay) / 60ms | *NOT SUPPORTED* |