Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Top Load Washer
Manufacturer: Whirlpool
Make: Whirlpool
Model Length: 10

Associated Models


CAE2743BQ0
CAE2743BQO
CAE2793BQ0

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0008

Part #: C-0301

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-6911

Desc 1: F2 Metercase Bracket

Desc 2: Whirlpool - White

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove the coin box and coin drop/slide from the machine's meter case.
  2. Attach the C-5414 Mounting Bracket to the C-6911 Meter Case Bracket using the (2) C-5420 10-32 x 1/4" Philips Screws.
  3. Insert the assembled C-6911 Meter Case Bracket into the front opening of the machine's meter case.
  4. Secure the C-6911 Meter Case Bracket into place by attaching the C-0301 Mounting Bolt to the cage nut at the top of the C-6911 Meter Case Bracket from inside the machine's meter case.
  5. After connecting all harnesses to the reader, use the (2) C-5416 8-32 x 3/8" Security Torx Screws to secure the reader to the C-5414 Mounting Bracket.

Connect Power

 I-P0003

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 3

Part #: C-5210

Desc 1: Power Adapter Harness

Desc 2: CGI

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Locate the incoming 120v power connection.
    1. The green ground wire should connect to points on the chassis and front panel.
    2. The black and white wires end in a white connector.
  2. Attach C-5101 Spade Tap to the black wire, white wire, and green ground wire.
  3. Connect the C-5210 Power Adapter Harness to the spade taps.
    1. Blue wire to black wire.
    2. Brown wire to white wire.
    3. Green wire to green wire.
  4. Connect the 3-pin connector from the C-5210 Power Adapter Harness to the matching connector on the C-5602R1 Power Converter.
  5. Connect the 4-pin connector from the C-5602R1 Power Converter to the matching connector on the C-5500 Power Extension Harness.

Connect Machine Interface Harness

 I-T0068

Part #: C-5371

Desc 1: Machine Start Harness

Desc 2: MLG32PD

   Qty: 1

  1. Connect the 4-pin end of the C-5371 Machine Start Harness to the J5 connector on the coin slide interface board.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole.
  2. Connect the free end of the C-5371 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-5500 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.