Overview

Equipment Details

Type: Top Load Washer
Manufacturer: Whirlpool
Make: Whirlpool
Model Length: Not Set

Associated Models


CAE2745FQ
CAE2745FQ0
CAE2745FQ1

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0008

Part #: C-0301

Desc 1: Topload Mounting Bolt

Desc 2:

   Qty: 1

Part #: C-6911

Desc 1: F2 Metercase Bracket

Desc 2: Whirlpool - White

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove the coin box and coin slide from the machine's meter case.

  2. Attach the C-5414 Reader Bracket to the front of the C-6911 Meter Case Bracket using (2) C-5420 10-32 x 1/4 Pan Screws.

  3. Insert the assembled C-6911 Meter Case Bracket into the front opening of the machine's meter case.

  4. Secure the C-6911 Meter Case Bracket into place by attaching the C-0301 Mounting Bolt to the cage nut at the top of the C-6911 Meter Case Bracket from inside the meter case.

Connect Power

Connect Machine Interface Harness

 I-T0068

Part #: C-5371

Desc 1: Machine Start Harness

Desc 2: MLG32PD

   Qty: 1

  1. Connect the 4-pin end of the C-5371 Machine Start Harness to the J5 connector on the coin slide interface board.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole.

  2. Connect the free end of the C-5371 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. Connect the free end of the C-5500 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.