Overview
Equipment Details
Type: Washer
Manufacturer: Laundrylux
Make: Wascomat
Model Length: 4
Associated Models
E620
E625
E630
E640
E650
E655
E675
Installation
Install Mounting Hardware
I-M0131
Part #: C-1059
Desc 1: Nut
Desc 2: 10-32 - Kep
Qty: 2
Part #: C-6920R1
Desc 1: Mounting Bracket
Desc 2: 6" Straight w/ studs
Qty: 1
Part #: C-5420
Desc 1: Screw
Desc 2: 10-32 x ¼" - Pan
Qty: 2
Part #: C-5416
Desc 1: Screw
Desc 2: 8-32" x 3/8" - Button - Torx
Qty: 2
Part #: C-5414
Desc 1: F2/F3 Std. Mounting Bracket
Desc 2: Sheet metal base
Qty: 1
Remove existing coin box and coin drop.
Attach the C-5414 Standard Mounting Bracket to the C-6920R1 Mounting Bracket using the C-5420 Screws.
Install the C-6920R1 Mounting Bracket into the coin vault opening. Secure in place using the C-1059 Kep Nuts.
Connect Power
Connect Coin Sense Harness
Connect Machine Interface Harness
Connect and Mount Reader
LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.
Secure the LaundryCard reader to the bracketry using included hardware.
LaundryCard L2 Reader (C-0103-L2)
Feed remaining harness ends through mounting bracket.
For serial setups:
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
For coin pulse setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F1 Reader (C-5001)
Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.
Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.
F2/FLEX Reader (C-5401, C-5402, C-5402E)
Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
For Serial Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
For Pulse Setups:
Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.
Connect the free end of the Power Harness to port 1.
Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.
F3 Reader (C-5520, C-5520E)
CCI Software Configuration
Machine Control | Pulse | Serial |
---|