Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer
Manufacturer: Milnor
Make: Milnor
Model Length: 8

Associated Models


36021C4E

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

Connect Power

Connect Coin Sense Harness

 I-C0011

Part #: C-6310

Desc 1: Combination Harness

Desc 2: Gen Pulse Sense Eye

   Qty: 1

  1. Disconnect the coin sensor from Terminal Board C.

  2. Connect the wires from the coin sensor to the three circuit screw down terminal with the blue, green, and red wires.

    1. Pair the harness wires to the same colored wires from the coin sensor.

  3. Disconnect the wires from the door switch and connect the white wires with female spade terminal connectors to the same locations.

Connect Machine Interface Harness

 I-C0011

Part #: C-6310

Desc 1: Combination Harness

Desc 2: Gen Pulse Sense Eye

   Qty: 1

  1. Connect the wires from the Terminal Board C to the three circuit screw down terminal with the blue, green, and black wires.

    1. Pair the machine wires to the the following screw down terminal wires:

      1. Blue wire to blue.

      2. Green wire to green.

      3. Red wire to black.

  2. Take the wires previously connected to the door switch and connect the white wires with male spade terminal connectors to the wires.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole.

  2. Connect the larger, white 6-pin connector of the C-6310 Combination Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. (Coin and Card Installation Only) Connect the smaller, white 5-pin connector of the C-6310 Combination Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  4. Connect the free end of the C-5500 Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.