Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer
Manufacturer: Alliance
Make: IPSO
Model Length: 5

Associated Models


WE181

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2/F3 Mounting Guide for further instructions.

 I-M0061

Part #: C-0015

Desc 1: Label

Desc 2: Reader Cover Label

   Qty: 1

Part #: C-0031

Desc 1: Label

Desc 2: Dexter Instruction Panel

   Qty: 1

Part #: C-0144

Desc 1: Screw

Desc 2: 8-32 x 2" - Flat

   Qty: 2

Part #: C-0905

Desc 1: Drop Cover

Desc 2: 2-3/8" x 4-5/8"

   Qty: 1

Part #: C-0960

Desc 1: Mounting Bracket

Desc 2: IPSO

   Qty: 1

Part #: C-0961

Desc 1: Jam ring

Desc 2: IPSO

   Qty: 1

Part #: C-1043

Desc 1: Screw

Desc 2: 8-32 x 1-3/4" - Flat

   Qty: 2

  1. Install the C-0961 Jam Ring into the coin vault. The Jam Ring should be installed into the coin vault so that it is within 1.5" of front panel of the machine to allow the mounting bracket to be attached.

  2. To install the Jam Ring insert the ring so the small portion is on the bottom. Insert at an angle, so the top of the Jam Ring is inserted first. Once the ring is in position, pull the top of the Jam Ring towards the front of the machine until it locks into place.

  3. Using the C-0144 Screws, attach the C-0960 Mounting Bracket to the C-0961 Jam Ring.

  4. Secure reader to C-0960 Mounting Bracket using C-1043 Screw.

  5. Install the C-0905 Drop Cover where the coin drop was installed. Secure using the original hardware.

  6. Apply C-0031 Label over the C-0905 Drop Cover.

 I-M0133

Part #: C-0905

Desc 1: Drop Cover

Desc 2: 2-3/8" x 4-5/8"

   Qty: 1

Part #: C-0961

Desc 1: Jam ring

Desc 2: IPSO

   Qty: 1

Part #: C-5751

Desc 1: Screw

Desc 2: 8-32 x 2-1/2" - Flat

   Qty: 2

Part #: C-6960

Desc 1: IPSO Mounting Brkt

Desc 2: Powder coated black

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Install the C-0961 Jam Ring into the coin vault. The Jam Ring should be installed into the coin vault so that it is within 1.5" of front panel of the machine to allow the mounting bracket to be attached.

  2. To install the Jam Ring insert the ring so the small portion is on the bottom. Insert at an angle, so the top of the Jam Ring is inserted first. Once the ring is in position, pull the top of the Jam Ring towards the front of the machine until it locks into place.

  3. Using the C-5751 Screws, attach the C-6960 Mounting Bracket to the C-0961 Jam Ring.

  4. Attach the C-5414 Standard Mounting Bracket to the C-6960 Mounting Bracket using the C-5420 Screws.

 I-M0142

Part #: C-5800

Desc 1: F1 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F1 Reader Mounting Guide for further instructions.

 I-M0216

Part #: C-6802

Desc 1: FLEX RF Reader Mounting Kit

Desc 2:

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2/F3 Mounting Guide for further instructions.

Instructions do not exist for Kit I-M0249

Connect Power

 I-P0003

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 3

Part #: C-5210

Desc 1: Power Adapter Harness

Desc 2: CGI

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.

  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.

  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

 I-S0004

Part #: C-5253

Desc 1: Coin Sense Harness

Desc 2: 28"

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-5253 Coin Sense Harness to the harness connected to the Coin Drop.

 I-S0031

Part #: C-6253

Desc 1: Coin Sense Harness

Desc 2: 28"

   Qty: 1

  1. Disconnect the factory harness from the micro switch tabs on the Coin Drop.

  2. Connect the C-6253 Coin Sense Harness to the micro switch tabs in any pairing.

Connect Machine Interface Harness

 I-T0016

Part #: C-0113

Desc 1: Machine Start Harness

Desc 2: 2-Wire Harness

   Qty: 1

  1. Remove the harness connected to the microswitch mounted to the coin drop. Connect the C-0113 Machine Start Harness to the harness previously connected to the microswitch.

 I-T0040

Part #: C-5256

Desc 1: Machine Start Harns (pulse)

Desc 2: 20" - Male taps, Rq. Female

   Qty: 1

  1. Connect the C-5256 Machine Start Harness to the harness previously connected to the micro switch on the coin drop/slide.

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)