Tools Needed - Phillips Head Screw Driver
- Unplug cable from card dispenser and empty the card hopper.
- Remove the bill acceptor cassette to allow for better access to the bottom of the card dispenser tray.
- Remove 4 phillips head screws on the bottom.
Remove old card dispenser and replace with new.
Leave screws loose when attaching new card dispenser to allow for adjusting the alignment of the card dispenser.
- Align card dispenser so that the feed tray is flush with the door slot.
- Once in place tighten the screws to secure the card dispenser from moving.
- Replace the bill acceptor cassette.
- Plug in cables to the card dispenser and reload the cards into the hopper.
- Test by opening up the diagnostic program and dispensing cards. If needed, adjust the bar code reader to ensure consistent reads.